EUVIMEDEUVIMED entdecken
Open Access

Evaluation of Vessel Enhancement Software for Improved Cerebrovascular Visualization in 3D Rotational Angiography

Niclas Schmitt iD, Andreas Berting, Lena Wucherpfennig iD, Fabian Preisner, Christoph M Mooshage iD, Sophia Hohenstatt iD, Martin Bendszus iD, Markus A Möhlenbruch iD, Dominik F Vollherbst iD

American Journal of Neuroradiology · 2026

DOI: 10.3174/ajnr.a9248 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Neuroradiology, 2026. Verfasst von Niclas Schmitt und 8 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Neuroradiology (N.S., F.P., C.M.M., S.H., M.B., M.A.M., D.F.V.), Heidelberg University Hospital, Heidelberg, Germany Niclas.Sc…. Hauptthemen laut MEDLINE: Cerebral Angiography, Imaging, Three-Dimensional, Software, Intracranial Aneurysm. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: 3D rotational angiography (3D-RA) is a key technique in endovascular neurointerventions but often provides limited visibility of small, clinically-relevant vessels such as perforating arteries. This study aimed to evaluate the performance of a novel, dedicated vessel-enhancement software in improving vascular visibility in 3D-RA data sets. MATERIALS AND METHODS: In this retrospective analysis of a prospectively maintained institutional database, 50 consecutive patients with unruptured anterior circulation aneurysms underwent standardized 3D-RA acquisitions on the Artis icono angiographic system. Each data set was reconstructed with and without vessel enhancement (VE). Quantitative analysis comprised contrast-to-noise ratio (CNR) measurements in the M1 segment of the MCA and in perforating branches. Qualitative image quality was independently assessed by 2 experienced readers on a 5-point scale. RESULTS: VE yielded consistent improvements across all analyses. CNR increased in the M1 segment (mean CNR, no VE: 25.15 [SD, 5.42] versus VE: 27.85 [SD 5.41], P < .001) and in the perforating arteries (mean CNR, no vessel enhancement: 22.26 [SD, 4.57] versus VE: 24.80 [SD, 4.75], P < .001). Overall qualitative ratings improved from "very good" to "excellent" diagnostic quality, with higher scores for vessel-enhanced reconstructions compared with unenhanced images (mean score [SD], no VE: 3.90 [SD, 0.65] versus VE: 4.66 [SD, 0.52], P < .001). Improvements were particularly evident for the continuity and visibility of fine vascular structures. Inter-reader agreement was good (κ = 0.72), supporting the robustness of the findings. CONCLUSIONS: Dedicated VE software improves the depiction of both larger arteries and small perforating branches in cerebral 3D-RA. By enabling clearer visualization of fine vascular structures, this approach may strengthen diagnostic confidence and procedural safety in complex endovascular neurointerventions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cerebral AngiographyImaging, Three-DimensionalSoftwareIntracranial AneurysmRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedHumansFemaleRetrospective StudiesMaleReproducibility of ResultsAgedMiddle AgedSensitivity and Specificity

Autor:innen und Institutionen

  • From the Department of Neuroradiology (N.S., F.P., C.M.M., S.H., M.B., M.A.M., D.F.V.), Heidelberg University Hospital, Heidelberg, Germany Niclas.Schmitt@med.uni-heidelberg.de.
  • Clinical Segment Interventional Radiology (A.B.), Neurovascular, Siemens Healthineers, Forchheim, Germany.
  • Department of Diagnostic and Interventional Radiology (L.W.), Heidelberg University Hospital, Heidelberg, German.
  • Translational Lung Research Center Heidelberg (L.W.), German Center for Lung Research, Heidelberg, Germany.
  • Department of Diagnostic and Interventional Radiology with Nuclear Medicine (L.W.), Thoraxklinik Heidelberg, University Hospital, Heidelberg, Germany.
  • From the Department of Neuroradiology (N.S., F.P., C.M.M., S.H., M.B., M.A.M., D.F.V.), Heidelberg University Hospital, Heidelberg, Germany.

ORCID-Profile: Niclas Schmitt, Lena Wucherpfennig, Christoph M Mooshage, Sophia Hohenstatt, Martin Bendszus, Markus A Möhlenbruch, Dominik F Vollherbst

Förderung

  • Siemens Healthineers

Zitieren

APA

Schmitt, N., Berting, A., Wucherpfennig, L., Preisner, F., Mooshage, C. M., Hohenstatt, S., Bendszus, M., Möhlenbruch, M. A., & Vollherbst, D. F. (2026). Evaluation of Vessel Enhancement Software for Improved Cerebrovascular Visualization in 3D Rotational Angiography. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a9248

Vancouver

Schmitt N, Berting A, Wucherpfennig L, Preisner F, Mooshage CM, Hohenstatt S, et al. Evaluation of Vessel Enhancement Software for Improved Cerebrovascular Visualization in 3D Rotational Angiography. American Journal of Neuroradiology. 2026. doi:10.3174/ajnr.a9248

BibTeX
@article{Schmitt2026,
  author = {Schmitt, Niclas and Berting, Andreas and Wucherpfennig, Lena and Preisner, Fabian and Mooshage, Christoph M and Hohenstatt, Sophia and Bendszus, Martin and Möhlenbruch, Markus A and Vollherbst, Dominik F},
  title = {Evaluation of Vessel Enhancement Software for Improved Cerebrovascular Visualization in 3D Rotational Angiography},
  journal = {American Journal of Neuroradiology},
  year = {2026},
  doi = {10.3174/ajnr.a9248}
}
Kostenlos starten →