EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Sources of Variability in Intracranial Aneurysm Model Reconstruction and Evaluation: A Systematic Investigation

Jared T Chong, Hang Yi, Alex E Wang, Cindy Ju, Luke Bramlage, Bryan Ludwig, Zifeng Yang

Cardiovascular Engineering and Technology · 2026-08 · 17 (4) · 414-424

DOI: 10.1007/s13239-026-00841-1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Cardiovascular Engineering and Technology, online erschienen am 07.05.2026. Verfasst von Jared T Chong und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Materials Engineering, Wright State University, Dayton, OH, 45435, USA. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Radiographic Image Interpretation, Computer-Assisted, Models, Cardiovascular, Cerebral Angiography. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Premier Health and Boonshoft School of Medicine Endowment Funding at Wright State University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The intracranial aneurysm (IA) model reconstruction is critical for pathophysiology diagnosis and computational simulations. This study aimed to quantify the impact of segmentation thresholds and software platforms on the reconstruction of IA geometry as well as the impact of inter-user variability on the assessment of morphology.

Methods

600 IA models were reconstructed from 100 patient DSA datasets using Materialise Mimics and 3D Slicer at three grey value (GV) thresholds; 1000, 1500, and 2500. Geometric measurements were performed in 3-matic by three users. Measurements included vessel diameters and aneurysm morphology parameters. Mimics, the 2500 GV threshold, and the most experienced user (R1) served as baselines for comparison. Normality was evaluated using Shapiro-Wilk tests, and statistical differences were assessed with paired t-tests and relative percent differences.

Results

All anatomical regions showed statistically significant geometric variation across software and threshold. Model evaluation showed potential statistically significant variation between users. Models from 3D Slicer were consistently smaller than those from Mimics with percent differences ranging from − 1.27 to − 4.38% (all p < .05). Lower thresholds produced consistently larger models; decreasing from 2500 to 1000 GV increased average diameters by up to 15.9%, depending on specific region. User-related variability was most pronounced in the least experienced user, with size measurements deviating by up to 22.67% from the baseline.

Conclusion

Segmentation software, threshold selection, and user interaction each introduce meaningful and statistically significant variability into IA model geometry and evaluation. Standardization of segmentation protocols—especially threshold values and operator training—is essential to improve reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intracranial AneurysmRadiographic Image Interpretation, Computer-AssistedModels, CardiovascularCerebral AngiographyAngiography, Digital SubtractionImaging, Three-DimensionalPatient-Specific ModelingHumansReproducibility of ResultsPredictive Value of TestsObserver VariationSoftwareFemaleMaleMiddle Aged

Stichwörter der Autor:innen

AneurysmModelReconstructionThreshold

Autor:innen und Institutionen

  • Department of Mechanical and Materials Engineering, Wright State University, Dayton, OH, 45435, USA.
  • Centerville High School, 500 E Franklin St, Centerville, OH, 45459, USA.
  • Upper Arlington High School, 1625 Zollinger Rd, Upper Arlington, OH, 43221, USA.
  • Division of NeuroInterventional Surgery, Department of Neurology, Wright State University/Premier Health-Clinical Neuroscience Institute, 30E. Apple St., Dayton, OH, 45409, USA.
  • Boonshoft School of Medicine, Wright State University, Dayton, OH, 45435, USA.
  • Department of Mechanical and Materials Engineering, Wright State University, Dayton, OH, 45435, USA. zifeng.yang@wright.edu.

Förderung

  • Premier Health and Boonshoft School of Medicine Endowment Funding at Wright State University

Zitieren

APA

Chong, J. T., Yi, H., Wang, A. E., Ju, C., Bramlage, L., Ludwig, B., & Yang, Z. (2026). Sources of Variability in Intracranial Aneurysm Model Reconstruction and Evaluation: A Systematic Investigation. Cardiovascular Engineering and Technology, 17(4), 414-424. https://doi.org/10.1007/s13239-026-00841-1

Vancouver

Chong JT, Yi H, Wang AE, Ju C, Bramlage L, Ludwig B, et al. Sources of Variability in Intracranial Aneurysm Model Reconstruction and Evaluation: A Systematic Investigation. Cardiovascular Engineering and Technology. 2026;17(4):414-424. doi:10.1007/s13239-026-00841-1

BibTeX
@article{Chong2026,
  author = {Chong, Jared T and Yi, Hang and Wang, Alex E and Ju, Cindy and Bramlage, Luke and Ludwig, Bryan and Yang, Zifeng},
  title = {Sources of Variability in Intracranial Aneurysm Model Reconstruction and Evaluation: A Systematic Investigation},
  journal = {Cardiovascular Engineering and Technology},
  year = {2026},
  volume = {17},
  number = {4},
  pages = {414--424},
  doi = {10.1007/s13239-026-00841-1}
}
Kostenlos starten →