Analysis of predictors of paravalvular leakage after transcatheter aortic valve implantation with fifth-generation self-expandable valve

Motoki Kojima, Shinichiro Fujimoto, Masahiko Noguchi, Yui Okada Nozaki, Hideyuki Sato, Yuko Okano Kawaguchi, Nobuo Tomizawa, Shinichiro Doi, Shinya Okazaki, Kazuhiko Doryo, Yosuke Kogure, Minoru Tabata und 1 weitere

Cardiovascular Intervention and Therapeutics · 2026

DOI: 10.1007/s12928-025-01188-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiovascular Intervention and Therapeutics, 2026. Verfasst von Motoki Kojima und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, 2-1-1 Hongo Bunkyo-Ku, Tokyo, 113-8421, Japan. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis, Heart Valve Prosthesis, Aortic Valve. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Paravalvular leakage (PVL) is one of the complications of transcatheter aortic valve implantation (TAVI), and its occurrence has been reported to affect long-term prognosis. We investigated whether the aortic valve calcification measured on preoperative CT is useful in predicting PVL after TAVI using the fifth-generation self-expanding valves. We analyzed 88 consecutive patients who underwent TAVI with the fifth-generation self-expanding valve from March 2023 to March 2024. Significant PVL was defined as PVL of mild or greater based on postoperative echocardiography results. We performed logistic regression analysis to evaluate whether patient background, and aortic valve calcification volume (AVCa-Vol), maximum CT value (AVCa-Max), mean CT value (AVCa-Ave), Agatston score (AV-Aga) and left ventricular outflow tract (LVOT) calcification volume measured by ECG-gated non-contrast CT were significant predictors. Mild or greater PVL was observed in 26 patients (29.5%). AVCa-Vol (1948.9 mm3 vs 1427.9 mm3, P < 0.01), AV-Aga (2412.8 vs 1743.7, P < 0.01), and LVOT calcification volume (109.8 vs 28.6, P < 0.01) were significantly higher in the PVL group. Univariate logistic regression analysis identified AVCa-Vol and AV-Aga as significant predictors, and they remained independent predictors after adjustment for age and sex (AVCa-Vol: odds ratio (OR) 2.91 (95% Confidence Interval (CI) 1.36-6.20), P < 0.01, AV-Aga: OR 2.24 (95% CI 1.25-4.03), P < 0.01). Receiver operating characteristic analysis showed optimal cutoff values for AVCa-Vol at 1665.13 mm3 (Area under the curve (AUC) = 0.73) and AV-Aga at 1908.59 (AUC = 0.72). AVCa-Vol and AV-Aga were identified as significant predictors of PVL occurrence after TAVI using the fifth-generation self-expandable valve.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisHeart Valve ProsthesisAortic ValvePostoperative ComplicationsCalcinosisHumansMaleFemaleAged, 80 and overRetrospective StudiesAgedProsthesis DesignEchocardiographyTomography, X-Ray ComputedRisk Factors

Stichwörter der Autor:innen

CalcificationParavalvular leakageSelf-expandableTranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, 2-1-1 Hongo Bunkyo-Ku, Tokyo, 113-8421, Japan.
  • Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, 2-1-1 Hongo Bunkyo-Ku, Tokyo, 113-8421, Japan. s-fujimo@tj8.so-net.ne.jp.
  • Department of Cardiology, Tokyo Bay Urayasu Ichikawa Medical Center, Urayasu, Japan.
  • Department of Diagnostic Radiological Technology, Juntendo University Hospital, Tokyo, Japan.
  • Department of Radiology, Juntendo University Hospital, Tokyo, Japan.
  • Department of Radiological Technology, Juntendo University Nerima Hospital, Tokyo, Japan.

Zitieren

APA

Kojima, M., Fujimoto, S., Noguchi, M., Nozaki, Y. O., Sato, H., Kawaguchi, Y. O., Tomizawa, N., Doi, S., Okazaki, S., Doryo, K., Kogure, Y., Tabata, M., & Minamino, T. (2026). Analysis of predictors of paravalvular leakage after transcatheter aortic valve implantation with fifth-generation self-expandable valve. Cardiovascular Intervention and Therapeutics. https://doi.org/10.1007/s12928-025-01188-5

Vancouver

Kojima M, Fujimoto S, Noguchi M, Nozaki YO, Sato H, Kawaguchi YO, et al. Analysis of predictors of paravalvular leakage after transcatheter aortic valve implantation with fifth-generation self-expandable valve. Cardiovascular Intervention and Therapeutics. 2026. doi:10.1007/s12928-025-01188-5

BibTeX
@article{Kojima2026,
  author = {Kojima, Motoki and Fujimoto, Shinichiro and Noguchi, Masahiko and Nozaki, Yui Okada and Sato, Hideyuki and Kawaguchi, Yuko Okano and Tomizawa, Nobuo and Doi, Shinichiro and Okazaki, Shinya and Doryo, Kazuhiko and Kogure, Yosuke and Tabata, Minoru and Minamino, Tohru},
  title = {Analysis of predictors of paravalvular leakage after transcatheter aortic valve implantation with fifth-generation self-expandable valve},
  journal = {Cardiovascular Intervention and Therapeutics},
  year = {2026},
  doi = {10.1007/s12928-025-01188-5}
}
Kostenlos starten →