EUVIMEDEUVIMED entdecken
Crossref

Diagnostic utility of velocity ratio for paradoxical low-flow/low-gradient aortic stenosis

Shun Nagai, Takayoshi Toba, Yu Izawa, Kei Honde, Ken-Ichi Hirata, Hidekazu Tanaka

Journal of Echocardiography · 2024

DOI: 10.1007/s12574-024-00659-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Echocardiography, 2024. Verfasst von Shun Nagai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe…. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Aortic Valve. Die Arbeit nennt 9 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Calcification score by cardiac computed tomography (CT) is required for diagnosis of paradoxical low-flow/low-gradient (PLFLG) aortic stenosis (AS). According to the guideline, velocity ratio (VR) < 0.25 by echocardiography is defined as severe AS, but utility of VR in patients with PLFLG AS remains unknown. This retrospective study was therefore conducted to investigate the utility of VR for a diagnosis of severe AS based on CT in patients with PLFLG AS. METHODS: We studied 58 patients with PLFLG AS. Severity of AS was defined as calcium score derived from cardiac CT. RESULTS: Of the 58 patients, 28 (48.3%) were diagnosed with severe AS based on CT, while 23 of them (82.1%) had VR < 0.25. It was noteworthy that receiver operating characteristic curve analysis showed that the optimal VR cutoff value for a diagnosis of severe AS was 0.25, with an area under the curve of 0.870 (P < 0.001). Sensitivity, specificity, positive predictive value, and negative predictive value of VR < 0.25 for a diagnosis of severe AS were 82.1%, 86.7%, 85.2% and 83.9%, respectively. Furthermore, patients who match the value of VR and severity of AS based on CT had higher prevalence of atrial fibrillation, higher serum brain natriuretic peptide concentration, larger left ventricular end-diastolic volume, and left ventricular stroke volume index. CONCLUSION: The measurement of VR is simple, and VR < 0.25 can be used for diagnosis of patients with PLFLG AS as severe. Our findings may thus have clinical implications for routine clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisAortic ValveHumansMaleFemaleRetrospective StudiesAgedSeverity of Illness IndexTomography, X-Ray ComputedEchocardiographyROC CurveMiddle AgedAged, 80 and overBlood Flow VelocityPredictive Value of TestsSensitivity and SpecificityCalcinosis

Stichwörter der Autor:innen

Cardiac computed tomographyEchocardiographyLow-flow/low-gradient aortic stenosisVelocity ratio

Autor:innen und Institutionen

  • Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
  • Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan. tanakah@med.kobe-u.ac.jp.

Zitieren

APA

Nagai, S., Toba, T., Izawa, Y., Honde, K., Hirata, K. I., & Tanaka, H. (2024). Diagnostic utility of velocity ratio for paradoxical low-flow/low-gradient aortic stenosis. Journal of Echocardiography. https://doi.org/10.1007/s12574-024-00659-7

Vancouver

Nagai S, Toba T, Izawa Y, Honde K, Hirata KI, Tanaka H. Diagnostic utility of velocity ratio for paradoxical low-flow/low-gradient aortic stenosis. Journal of Echocardiography. 2024. doi:10.1007/s12574-024-00659-7

BibTeX
@article{Nagai2024,
  author = {Nagai, Shun and Toba, Takayoshi and Izawa, Yu and Honde, Kei and Hirata, Ken-Ichi and Tanaka, Hidekazu},
  title = {Diagnostic utility of velocity ratio for paradoxical low-flow/low-gradient aortic stenosis},
  journal = {Journal of Echocardiography},
  year = {2024},
  doi = {10.1007/s12574-024-00659-7}
}
Kostenlos starten →