Extracellular Volume Remodeling After Transcatheter Aortic Valve Implantation: Factors Associated With Indexed Extracellular Volume Worsening
Catheterization and Cardiovascular Interventions · 2026-11 · 108 (6) · 2118-2129
DOI: 10.1002/ccd.70884 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 17.09.2026. Verfasst von Yutaka Matsuhiro und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, The University of Osaka Graduate School of Medicine, Osaka, Japan. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Transcatheter Aortic Valve Replacement, Ventricular Remodeling, Aortic Valve. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Background
Data remain limited regarding whether extracellular volume (ECV) measured by computed tomography (CT) changes after transcatheter aortic valve implantation (TAVI), and which clinical factors may be associated with its temporal evolution.
Aims
The aim of this study was to evaluate changes in ECV after TAVI and to identify factors associated with these changes.
Methods
This retrospective, single‐center, hypothesis‐generating study included consecutive patients with severe aortic stenosis (AS) who underwent TAVI at Osaka University Hospital between March 2023 and January 2025 and had cardiac CT with delayed enhancement performed before the procedure and at 6‐month follow‐up. Left ventricular mass index (LVMi), indexed ECV, and indexed cellular volume were assessed by CT.
Results
Fifty‐five patients were included in the final analysis. At 6 months after TAVI, LVMi decreased significantly, with a median relative reduction of 21%. Both indexed ECV and indexed cellular volume decreased significantly, with median relative reductions of 15% and 22%, respectively. Because the reduction in indexed cellular volume exceeded that in indexed ECV, the ECV fraction increased significantly at follow‐up. An increase in indexed ECV at 6 months was observed in 16.4% of the cohort and was associated with worsening aortic regurgitation.
Conclusions
At 6 months after TAVI, CT‐derived indexed ECV was significantly reduced, suggesting early modification of the myocardial interstitium. In contrast, suboptimal hemodynamic relief may be associated with less favorable remodeling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, The University of Osaka Graduate School of Medicine, Osaka, Japan.
- Department of Cardiovascular Surgery, The University of Osaka Graduate School of Medicine, Osaka, Japan.
ORCID-Profile: Yutaka Matsuhiro, Daisuke Nakamura, Shumpei Kosugi, Koichi Maeda
Zitieren
APA
Matsuhiro, Y., Nakamura, D., Ide, S., Higashino, N., Sugae, H., Okuno, S., Kosugi, S., Kawamura, A., Maeda, K., Shimamura, K., Takeda, Y., Mizote, I., Miyagawa, S., & Sakata, Y. (2026). Extracellular Volume Remodeling After Transcatheter Aortic Valve Implantation: Factors Associated With Indexed Extracellular Volume Worsening. Catheterization and Cardiovascular Interventions, 108(6), 2118-2129. https://doi.org/10.1002/ccd.70884
Vancouver
Matsuhiro Y, Nakamura D, Ide S, Higashino N, Sugae H, Okuno S, et al. Extracellular Volume Remodeling After Transcatheter Aortic Valve Implantation: Factors Associated With Indexed Extracellular Volume Worsening. Catheterization and Cardiovascular Interventions. 2026;108(6):2118-2129. doi:10.1002/ccd.70884
BibTeX
@article{Matsuhiro2026,
author = {Matsuhiro, Yutaka and Nakamura, Daisuke and Ide, Seiko and Higashino, Naoko and Sugae, Hiroki and Okuno, Shota and Kosugi, Shumpei and Kawamura, Ai and Maeda, Koichi and Shimamura, Kazuo and Takeda, Yasuharu and Mizote, Isamu and Miyagawa, Shigeru and Sakata, Yasushi},
title = {Extracellular Volume Remodeling After Transcatheter Aortic Valve Implantation: Factors Associated With Indexed Extracellular Volume Worsening},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {108},
number = {6},
pages = {2118--2129},
doi = {10.1002/ccd.70884}
}
EUVIMED