EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AI-assisted computed tomography analysis for pre-procedural planning prior to TAVI

Mani Arsalan, Hanna Schneider, Kerstin Piayda, Philipp Christian Seppelt, Arnaud Van Linden, Stephan Fichtlscherer, Florian Hecker, David Leistner, Thomas Walther

Clinical Research in Cardiology · 2026-07 · 115 (7) · 1199-1206

DOI: 10.1007/s00392-025-02790-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Research in Cardiology, online erschienen am 12.11.2025. Verfasst von Mani Arsalan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, University Hospital of the Goethe University, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany. mani.arsalan@gmail.com. Hauptthemen laut MEDLINE: Aortic Valve, Aortic Valve Stenosis, Artificial Intelligence, Deep Learning. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Johann Wolfgang Goethe-Universität, Frankfurt am Main.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Several software programs have specifically been developed to analyse cardiac computed tomography prior to transcatheter aortic valve implantation (TAVI). However, they are not able to perform a complete analysis independently. We report the performance of a fully automated, deep learning-based algorithm for pre-procedural CT analysis as compared to the current clinical standard.

Methods

Patients with symptomatic severe aortic stenosis undergoing TAVI were retrospectively enrolled. The pre-procedural dataset was analysed by both a standard TAVI CT-analysis software and by a fully automated CT analysis platform with a deep learning-based algorithm.

Results

Ninety-eight patients were included in the analysis. The mean annulus diameter was 24.4 ± 2.4 mm (conventional = 3mensio, Pie Medical Imaging, 3 M) vs. 24.0 ± 2.4 mm (artificial intelligence = AI), mean absolute error (MAE): 0.64 mm, mean absolute percentage error (MAPE): 2.6%. The mean annulus perimeter was measured at 77.7 ± 7.4 mm (3 M) vs. 76.1 ± 7.5 mm (AI), MAE: 2.26 mm, MAPE: 2.9%. The mean annulus area was calculated at 468.9 ± 92.1 mm 2 (3 M) vs. 455.6 ± 91.0 mm 2 (AI), MAE: 22.4 mm 2 , MAPE: 4.8%. The intraclass correlation coefficients (ICCs) of all abovementioned parameter were > 0.95 showing an excellent correlation between the two methods. The distance from the annulus to the left coronary artery depicted to 14.0 ± 3.2 mm (3 M) vs. 12.6 ± 2.8 mm (AI), MAE: 2.1 mm, MAPE: 14.3%. The distance to the right coronary artery was 17.1 ± 2.7 mm (3 M) vs. 16.5 ± 3.2 mm (AI), MAE: 1.7 mm, MAPE: 10.1%. The ICCs of the distances to the coronary ostia showed good correlation between both methods.

Conclusion

In this retrospective analysis, a deep learning-based analysis of pre-procedural CT datasets showed good to excellent correlation with conventional assessment for the preprocedural TAVI CT measurements. AI-based fully automated CT analysis could emerge to a valuable alternative to conventional CT assessment in the pre-procedural-planning for TAVI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic ValveAortic Valve StenosisArtificial IntelligenceDeep LearningRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansMaleAlgorithmsRetrospective StudiesSeverity of Illness Index

Stichwörter der Autor:innen

Aortic valveArtificial intelligenceComputed tomographyDeep-learningTranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Department of Cardiac Surgery, University Hospital of the Goethe University, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany. mani.arsalan@gmail.com.
  • Department of Cardiology and Angiology, Medical Clinic I, University Hospital of the Justus Liebig University, Klinikstrasse 33, 35392, Giessen, Germany. mani.arsalan@gmail.com.
  • Department of Cardiac Surgery, University Hospital of the Goethe University, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Department of Cardiology and Angiology, Medical Clinic I, University Hospital of the Justus Liebig University, Klinikstrasse 33, 35392, Giessen, Germany.
  • Department of Cardiology & Angiology, Medical Clinic III, University Hospital of the Goethe University, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Department of Cardiothoracic and Thoracic Vascular Surgery, University Hospital Würzburg, Würzburg, Germany.

Förderung

  • Johann Wolfgang Goethe-Universität, Frankfurt am Main

Zitieren

APA

Arsalan, M., Schneider, H., Piayda, K., Seppelt, P. C., Van Linden, A., Fichtlscherer, S., Hecker, F., Leistner, D., & Walther, T. (2026). AI-assisted computed tomography analysis for pre-procedural planning prior to TAVI. Clinical Research in Cardiology, 115(7), 1199-1206. https://doi.org/10.1007/s00392-025-02790-6

Vancouver

Arsalan M, Schneider H, Piayda K, Seppelt PC, Van Linden A, Fichtlscherer S, et al. AI-assisted computed tomography analysis for pre-procedural planning prior to TAVI. Clinical Research in Cardiology. 2026;115(7):1199-1206. doi:10.1007/s00392-025-02790-6

BibTeX
@article{Arsalan2026,
  author = {Arsalan, Mani and Schneider, Hanna and Piayda, Kerstin and Seppelt, Philipp Christian and Van Linden, Arnaud and Fichtlscherer, Stephan and Hecker, Florian and Leistner, David and Walther, Thomas},
  title = {AI-assisted computed tomography analysis for pre-procedural planning prior to TAVI},
  journal = {Clinical Research in Cardiology},
  year = {2026},
  volume = {115},
  number = {7},
  pages = {1199--1206},
  doi = {10.1007/s00392-025-02790-6}
}
Kostenlos starten →