EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validity of a simple spillover correction for positron emission tomography measurements in the cerebrospinal fluid region

Emi Hayashi, Shin Hibino, Mitsuhito Mase

Radiological Physics and Technology · 2025

DOI: 10.1007/s12194-025-00972-5 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Radiological Physics and Technology, 2025. Verfasst von Emi Hayashi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Planning and Research Bureau, Nagoya City Rehabilitation Agency, 1-2, Mikan-yama, Yotomi-cho, Mizuho-ku, Nagoya, Aichi, Japan. emilin0305@gmail.com. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Cerebrospinal Fluid, Image Processing, Computer-Assisted. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Positron emission tomography (PET) measurements in the cerebrospinal fluid (CSF) region may be overestimated because of spillover artifacts from surrounding radioactivity. In this study, we proposed a simple spillover correction method (subtraction method) and evaluated its validity. A cylindrical phantom simulating brain ventricles was used to compare the subtraction method with the geometric transfer matrix (GTM) correction approach. And the subtraction method was applied to dynamic PET images of [ 18 F]fluorodeoxyglucose (FDG), [ 18 F]fluorodopa (FDOPA), and [ 11 C]raclopride (RAC), and [ 15 O]H 2 O (H 2 O). The effects of spillover correction on CSF measurements were assessed. Both methods effectively reduced spillover artifacts in the phantom study. In dynamic PET images, after spillover correction, time–activity curves for FDG, FDOPA, and RAC approached near-zero levels in the CSF, whereas H 2 O continued to show increasing activity over time. This approach effectively reduces artifacts and offers the advantages of simpler volume-of-interest settings and straightforward calculation procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographyCerebrospinal FluidImage Processing, Computer-AssistedPhantoms, ImagingHumansArtifactsFluorodeoxyglucose F18Reproducibility of Results

Stichwörter der Autor:innen

CSFPETPartial volume correctionSpillover correction[15O]H2O

Substanzen

Fluorodeoxyglucose F18

Autor:innen und Institutionen

  • Planning and Research Bureau, Nagoya City Rehabilitation Agency, 1-2, Mikan-yama, Yotomi-cho, Mizuho-ku, Nagoya, Aichi, Japan. emilin0305@gmail.com.
  • Department of Medical Technology, Nagoya City University Rehabilitation Hospital, 1-2, Mikan-yama, Yatomi-cho, Mizuho-ku, Nagoya, Aichi, Japan. emilin0305@gmail.com.
  • Planning and Research Bureau, Nagoya City Rehabilitation Agency, 1-2, Mikan-yama, Yotomi-cho, Mizuho-ku, Nagoya, Aichi, Japan.
  • General Affairs Department, Nagoya City Rehabilitation Agency, 1-2, Mikan-yama, Yatomi-cho, Mizuho-ku, Nagoya, Aichi, Japan.
  • Department of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi, Japan.

Zitieren

APA

Hayashi, E., Hibino, S., & Mase, M. (2025). Validity of a simple spillover correction for positron emission tomography measurements in the cerebrospinal fluid region. Radiological Physics and Technology. https://doi.org/10.1007/s12194-025-00972-5

Vancouver

Hayashi E, Hibino S, Mase M. Validity of a simple spillover correction for positron emission tomography measurements in the cerebrospinal fluid region. Radiological Physics and Technology. 2025. doi:10.1007/s12194-025-00972-5

BibTeX
@article{Hayashi2025,
  author = {Hayashi, Emi and Hibino, Shin and Mase, Mitsuhito},
  title = {Validity of a simple spillover correction for positron emission tomography measurements in the cerebrospinal fluid region},
  journal = {Radiological Physics and Technology},
  year = {2025},
  doi = {10.1007/s12194-025-00972-5}
}
Kostenlos starten →