EUVIMEDEUVIMED entdecken
Crossref

Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on 18 F-FDG PET/CT

Yasutaka Ichikawa, Yoya Tomita, Kengo Hashizume, Hajime Sakuma

Journal of Nuclear Medicine Technology · 2025

DOI: 10.2967/jnmt.125.270294 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine Technology, 2025. Verfasst von Yasutaka Ichikawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mie University Hospital, Tsu, Mie, Japan yasutaka@med.mie-u.ac.jp. Hauptthemen laut MEDLINE: Artifacts, Positron Emission Tomography Computed Tomography, Fluorodeoxyglucose F18, Urinary Bladder. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite their clinical significance, the prevalence of bilateral low-accumulation bladder artifacts and the factors contributing to their occurrence in routine 18F-FDG PET/CT examinations have not been comprehensively studied. The aim of this study was to determine the prevalence of bilateral low-accumulation bladder artifacts and identify factors associated with their occurrence in clinical 18F-FDG PET/CT scans.

Methods

Patients (n = 112) who underwent 18F-FDG PET/CT for clinical purposes were retrospectively evaluated. PET images were reconstructed using 4 methods: 3-dimensional ordered-subset expectation maximization (OSEM) without time-of-flight (TOF); OSEM with TOF; Bayesian penalized likelihood (BPL) without TOF; and BPL with TOF. For non-TOF OSEM, PET images were reconstructed with and without scatter correction (SC). The SUVmax in the bladder was compared in patients with and without bilateral low-accumulation bladder artifacts. Phantom experiments with 2 external shapes were conducted, and the relationship between the radioactivity (0, 20, 50, 120, and 280 kBq/mL) of the 18F-FDG solution in the bladder-simulated sphere and the occurrence of the low-accumulation artifacts was evaluated.

Results

The prevalence of bilateral bladder artifacts was significantly lower in PET images reconstructed with TOF OSEM (7 patients; 6.3%), non-TOF BPL (3 patients; 2.7%), and TOF BPL (0 patients) compared with non-TOF OSEM (39 patients; 34.8%) (P < 0.001). Artifacts were also observed on PET images without SC. The median bladder SUVmax in patients with artifacts was significantly higher than that of patients without artifacts (59.8 vs. 28.5; P < 0.001). In phantom experiments using a rectangular model, bilateral bladder artifact intensity increased as the radioactivity in the simulated bladder increased on non-TOF reconstructions with and without SC. No artifacts were observed in experiments using a spheric phantom.

Conclusion

Bilateral low-accumulation bladder artifacts were observed in approximately 35% of clinical 18F-FDG PET/CT images reconstructed with non-TOF OSEM. Artifact occurrence was associated with radioactivity in the urinary bladder, independent of SC, and influenced by body shape. TOF and BPL reconstructions reduced artifact prevalence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsPositron Emission Tomography Computed TomographyFluorodeoxyglucose F18Urinary BladderHumansMaleFemaleMiddle AgedAgedPhantoms, ImagingRetrospective StudiesAdultAged, 80 and overImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Bayesian penalized likelihoodPETbilateral low-accumulation bladder artifacttime-of-flighturinary bladder

Substanzen

Fluorodeoxyglucose F18

Autor:innen und Institutionen

  • Department of Radiology, Mie University Hospital, Tsu, Mie, Japan yasutaka@med.mie-u.ac.jp.
  • Department of Radiology, Mie University Hospital, Tsu, Mie, Japan.

Zitieren

APA

Ichikawa, Y., Tomita, Y., Hashizume, K., & Sakuma, H. (2025). Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on 18 F-FDG PET/CT. Journal of Nuclear Medicine Technology. https://doi.org/10.2967/jnmt.125.270294

Vancouver

Ichikawa Y, Tomita Y, Hashizume K, Sakuma H. Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on 18 F-FDG PET/CT. Journal of Nuclear Medicine Technology. 2025. doi:10.2967/jnmt.125.270294

BibTeX
@article{Ichikawa2025,
  author = {Ichikawa, Yasutaka and Tomita, Yoya and Hashizume, Kengo and Sakuma, Hajime},
  title = {Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on 18 F-FDG PET/CT},
  journal = {Journal of Nuclear Medicine Technology},
  year = {2025},
  doi = {10.2967/jnmt.125.270294}
}
Kostenlos starten →