Validation of the collapsed‐cone superposition for whole‐body patient‐specific dosimetry in [177Lu]Lu‐PSMA‐617 radionuclide therapy
Medical Physics · 2025-08 · 52 (8)
DOI: 10.1002/mp.18076 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Medical Physics, online erschienen am 03.09.2025. Verfasst von Aya Terro und 7 weiteren Autor:innen. Beteiligte Einrichtung: QuantIF AIMS, University of Rouen, Rouen, France. Hauptthemen laut MEDLINE: Radiometry, Lutetium, Dipeptides, Heterocyclic Compounds, 1-Ring. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Région Normandie and Henri Becquerel Center.
Abstract (Originalsprache)
Background
Patient‐specific dosimetry in radiopharmaceutical therapy (RPT) offers a promising approach to optimize the balance between treatment efficacy and toxicity. The introduction of 360° CZT gamma cameras enables the development of personalized dosimetry studies using whole‐body single photon emission computed tomography and computed tomography (SPECT/CT) data.
Purpose
This study proposes to validate the collapsed‐cone superposition (CCS) approach against Monte Carlo (MC) simulations for whole‐body dosimetry of [177Lu]Lu‐PSMA‐617 therapy in patients with metastatic castration resistant prostate cancer (mCRPC). Materials and methods Thirty patients with mCRPC were retrospectively included in this study. SPECT/CT images were acquired after the infusion of [177Lu]Lu‐PSMA‐617 therapy. SimpleDose was used to generate dose‐rate maps (mGy/h) from a single SPECT/CT scan. The dosimetry relies on the CCS approach, which adjusts dose‐point kernels according to tissue densities. Organ and lesion delineation were automated using the nnU‐Net V2 neural network. MC simulations were performed with GATE 10 for 10 8 events. To assess the impact of density‐scaled DPK on the accuracy of the dosimetry, we implement a simplified version of CCS, denoted as , which assumes a homogeneous soft tissue medium without incorporating the patient‐specific density information derived from the CT image. The comparison between CCS, and MC was conducted at the organ, lesion, and voxel levels.
Results
Absolute percentage errors (APE) between CCS and MC were < 5% for all organs and lesions. Compared to CCS, exhibited higher APE with respect to MC in the liver, lungs, salivary glands, and lesions, while lower errors were observed in the bone marrow, kidneys, and pancreas, with comparable performance in the spleen. Voxel‐level errors were mostly < 2% for both methods CCS and . Median computation time was, respectively, 24.5 s, 46.45 s, and 6.8 h for CCS, , and MC.
Conclusion
CCS showed high agreement with MC with greater computational efficiency, demonstrating its clinical potential for whole‐body dosimetry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- QuantIF AIMS, University of Rouen, Rouen, France.
- Nuclear Medicine Department, Henri Becquerel Center, Rouen, France.
Förderung
- Région Normandie and Henri Becquerel Center
Zitieren
APA
Terro, A., Perret, S., Dumouchel, A., Tonnelet, D., Edet-Sanson, A., Vera, P., Decazes, P., & Dieudonné, A. (2025). Validation of the collapsed‐cone superposition for whole‐body patient‐specific dosimetry in [177Lu]Lu‐PSMA‐617 radionuclide therapy. Medical Physics, 52(8). https://doi.org/10.1002/mp.18076
Vancouver
Terro A, Perret S, Dumouchel A, Tonnelet D, Edet-Sanson A, Vera P, et al. Validation of the collapsed‐cone superposition for whole‐body patient‐specific dosimetry in [177Lu]Lu‐PSMA‐617 radionuclide therapy. Medical Physics. 2025;52(8). doi:10.1002/mp.18076
BibTeX
@article{Terro2025,
author = {Terro, Aya and Perret, Solène and Dumouchel, Arthur and Tonnelet, David and Edet-Sanson, Agathe and Vera, Pierre and Decazes, Pierre and Dieudonné, Arnaud},
title = {Validation of the collapsed‐cone superposition for whole‐body patient‐specific dosimetry in [177Lu]Lu‐PSMA‐617 radionuclide therapy},
journal = {Medical Physics},
year = {2025},
volume = {52},
number = {8},
doi = {10.1002/mp.18076}
}