EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Value of circulating tumor cell assisting low-dose computed tomography in screening pulmonary nodules based on existing liquid biopsy techniques: a systematic review with meta-analysis and trial sequential analysis

Yixian Wang, Yuqing Duan, Dingjie Guo, Hongbo Lv, Qiong Li, Xuan Liu, Na Qiao, Hengyu Meng, Xin Zhang, Linwei Lan, Xiumin Liu, Xin Liu

Clinical and Translational Oncology · 13.06.2024 · 26 (12) · 3252-3263

DOI: 10.1007/s12094-024-03556-8 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Clinical and Translational Oncology, online erschienen am 13.06.2024. Verfasst von Yixian Wang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China. Hauptthemen laut MEDLINE: Neoplastic Cells, Circulating, Lung Neoplasms, Tomography, X-Ray Computed, Multiple Pulmonary Nodules. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: This study aims to assess the diagnostic utility of circulating tumor cells (CTCs) in conjunction with low-dose computed tomography (LDCT) for differentiating between benign and malignant pulmonary nodules and to substantiate the foundation for their integration into clinical practice. METHODS: A systematic literature review was performed independently by two researchers utilizing databases including PubMed, Web of Science, The Cochrane Library, Embase, and Medline, to collate studies up to September 15, 2023, that investigated the application of CTCs in diagnosing pulmonary nodules. A meta-analysis was executed employing Stata 15.0 and Revman 5.4 to calculate the pooled sensitivity, specificity, positive and negative likelihood ratios (PLR and NLR), diagnostic odds ratio (DOR), and the area under the receiver operating characteristic curve (AUC). Additionally, trial sequential analysis was conducted using dedicated TSA software. RESULTS: The selection criteria identified 16 studies, encompassing a total of 3409 patients. The meta-analysis revealed that CTCs achieved a pooled sensitivity of 0.84 (95% CI 0.80 to 0.87), specificity of 0.80 (95% CI 0.73 to 0.86), PLR of 4.23 (95% CI 3.12 to 5.72), NLR of 0.20 (95% CI 0.16 to 0.25), DOR of 20.92 (95% CI 13.52 to 32.36), and AUC of 0.89 (95% CI 0.86 to 0.93). CONCLUSIONS: Circulating tumor cells demonstrate substantial diagnostic accuracy in distinguishing benign from malignant pulmonary nodules. The incorporation of CTCs into the diagnostic protocol can significantly augment the diagnostic efficacy of LDCT in screening for malignant lung diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neoplastic Cells, CirculatingLung NeoplasmsTomography, X-Ray ComputedMultiple Pulmonary NodulesHumansLiquid BiopsySensitivity and SpecificitySolitary Pulmonary NoduleEarly Detection of CancerROC CurveDiagnosis, Differential

Stichwörter der Autor:innen

Benign and malignantCTCMeta-analysisPulmonary nodulesTrial sequential analysis

Autor:innen und Institutionen

  • Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China.
  • Department of Clinical Laboratory, The Second Hospital of Jilin University, Changchun, Jilin, 130041, China. liuxium@jlu.edu.cn.
  • Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China. liuxinjlu01@163.com.

Zitieren

APA

Wang, Y., Duan, Y., Guo, D., Lv, H., Li, Q., Liu, X., Qiao, N., Meng, H., Zhang, X., Lan, L., Liu, X., & Liu, X. (2024). Value of circulating tumor cell assisting low-dose computed tomography in screening pulmonary nodules based on existing liquid biopsy techniques: a systematic review with meta-analysis and trial sequential analysis. Clinical and Translational Oncology, 26(12), 3252-3263. https://doi.org/10.1007/s12094-024-03556-8

Vancouver

Wang Y, Duan Y, Guo D, Lv H, Li Q, Liu X, et al. Value of circulating tumor cell assisting low-dose computed tomography in screening pulmonary nodules based on existing liquid biopsy techniques: a systematic review with meta-analysis and trial sequential analysis. Clinical and Translational Oncology. 2024;26(12):3252-3263. doi:10.1007/s12094-024-03556-8

BibTeX
@article{Wang2024,
  author = {Wang, Yixian and Duan, Yuqing and Guo, Dingjie and Lv, Hongbo and Li, Qiong and Liu, Xuan and Qiao, Na and Meng, Hengyu and Zhang, Xin and Lan, Linwei and Liu, Xiumin and Liu, Xin},
  title = {Value of circulating tumor cell assisting low-dose computed tomography in screening pulmonary nodules based on existing liquid biopsy techniques: a systematic review with meta-analysis and trial sequential analysis},
  journal = {Clinical and Translational Oncology},
  year = {2024},
  volume = {26},
  number = {12},
  pages = {3252--3263},
  doi = {10.1007/s12094-024-03556-8}
}
Kostenlos starten →