EUVIMEDEUVIMED entdecken
Vergleichsstudie

Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study

Yongfei Zhang, Geyu Du, Chengdong Li, Jun Qiang iD

British Journal of Radiology · 2026

DOI: 10.1093/bjr/tqag017 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Yongfei Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: The First Affiliated Hospital, College of Clinical Medicine, Medical College of Henan University of Science and Technology, Luoyang 471003, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Solitary Pulmonary Nodule, Lung Neoplasms, Multiple Pulmonary Nodules. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Henan Provincial Science and Technology Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To evaluate the diagnostic performance of tin-filtered 150 kV ultra-low-dose CT (ULDCT) for pulmonary nodule detection and size measurement, compared with standard-dose CT (SDCT).

Methods

This prospective study enrolled 261 patients who underwent both SDCT (120 kV) and ULDCT (150 kV with 0.6 mm tin filtration) during a single visit. Radiation dose parameters, subjective and objective image quality, and diagnostic performance were assessed using SDCT as the reference standard. Nodules were classified as solid, pure ground-glass nodules (pGGNs), or mixed ground-glass nodules (mGGNs), and nodule diameters were compared between the 2 protocols.

Results

ULDCT reduced radiation dose by 83% compared to SDCT (1.10 ± 0.22 vs 6.55 ± 1.51 mSv, P < .001) while maintaining excellent image quality. SDCT detected 856 nodules, with ULDCT identifying 779 true-positive nodules. Subtype analysis revealed sensitivities of 99.65% for solid nodules, 100% for mGGNs, and 70.12% for pGGNs. No significant differences were observed in nodule diameter measurements between ULDCT and SDCT (P > .05).

Conclusions

Tin-filtered 150 kV ULDCT achieves high sensitivity for pulmonary nodule detection with significantly reduced radiation dose, and maintains clinically acceptable image quality. Advances in knowledge This study provides clinical validation of tin-filtered 150 kV ULDCT in a heterogeneous outpatient population, demonstrating its feasibility for accurate pulmonary nodule detection beyond screening settings and highlighting its subtype-specific performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedSolitary Pulmonary NoduleLung NeoplasmsMultiple Pulmonary NodulesHumansProspective StudiesRadiation DosageFemaleSensitivity and SpecificityMaleAgedMiddle AgedTin

Stichwörter der Autor:innen

dual-source CTimage qualitylung cancer screeningpulmonary nodule detectionradiation dose reductionsubtype-specific sensitivitytin filtrationultra-low-dose CT

Substanzen

Tin

Autor:innen und Institutionen

  • The First Affiliated Hospital, College of Clinical Medicine, Medical College of Henan University of Science and Technology, Luoyang 471003, China.

ORCID-Profile: Jun Qiang

Förderung

  • Henan Provincial Science and Technology Research

Zitieren

APA

Zhang, Y., Du, G., Li, C., & Qiang, J. (2026). Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag017

Vancouver

Zhang Y, Du G, Li C, Qiang J. Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag017

BibTeX
@article{Zhang2026,
  author = {Zhang, Yongfei and Du, Geyu and Li, Chengdong and Qiang, Jun},
  title = {Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study},
  journal = {British Journal of Radiology},
  year = {2026},
  doi = {10.1093/bjr/tqag017}
}
Kostenlos starten →