Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study
British Journal of Radiology · 2026
DOI: 10.1093/bjr/tqag017 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Yongfei Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: The First Affiliated Hospital, College of Clinical Medicine, Medical College of Henan University of Science and Technology, Luoyang 471003, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Solitary Pulmonary Nodule, Lung Neoplasms, Multiple Pulmonary Nodules. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Henan Provincial Science and Technology Research.
Abstract (Originalsprache)
Background
To evaluate the diagnostic performance of tin-filtered 150 kV ultra-low-dose CT (ULDCT) for pulmonary nodule detection and size measurement, compared with standard-dose CT (SDCT).
Methods
This prospective study enrolled 261 patients who underwent both SDCT (120 kV) and ULDCT (150 kV with 0.6 mm tin filtration) during a single visit. Radiation dose parameters, subjective and objective image quality, and diagnostic performance were assessed using SDCT as the reference standard. Nodules were classified as solid, pure ground-glass nodules (pGGNs), or mixed ground-glass nodules (mGGNs), and nodule diameters were compared between the 2 protocols.
Results
ULDCT reduced radiation dose by 83% compared to SDCT (1.10 ± 0.22 vs 6.55 ± 1.51 mSv, P < .001) while maintaining excellent image quality. SDCT detected 856 nodules, with ULDCT identifying 779 true-positive nodules. Subtype analysis revealed sensitivities of 99.65% for solid nodules, 100% for mGGNs, and 70.12% for pGGNs. No significant differences were observed in nodule diameter measurements between ULDCT and SDCT (P > .05).
Conclusions
Tin-filtered 150 kV ULDCT achieves high sensitivity for pulmonary nodule detection with significantly reduced radiation dose, and maintains clinically acceptable image quality. Advances in knowledge This study provides clinical validation of tin-filtered 150 kV ULDCT in a heterogeneous outpatient population, demonstrating its feasibility for accurate pulmonary nodule detection beyond screening settings and highlighting its subtype-specific performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- The First Affiliated Hospital, College of Clinical Medicine, Medical College of Henan University of Science and Technology, Luoyang 471003, China.
ORCID-Profile: Jun Qiang
Förderung
- Henan Provincial Science and Technology Research
Zitieren
APA
Zhang, Y., Du, G., Li, C., & Qiang, J. (2026). Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag017
Vancouver
Zhang Y, Du G, Li C, Qiang J. Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag017
BibTeX
@article{Zhang2026,
author = {Zhang, Yongfei and Du, Geyu and Li, Chengdong and Qiang, Jun},
title = {Detection and size quantification of pulmonary nodules using ultra-low-dose CT with tin filtration: a prospective comparative study},
journal = {British Journal of Radiology},
year = {2026},
doi = {10.1093/bjr/tqag017}
}
EUVIMED