Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis
Radiology: Cardiothoracic Imaging · 2024
DOI: 10.1148/ryct.230241 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Radiology: Cardiothoracic Imaging, 2024. Verfasst von César Campagnolo Cavion und 8 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Radiology, Pontifícia Universidade Católica do Rio Grande do Sul, Av Ipiranga, 6681 - Partenon, Porto Alegre, Rio Grande do Su…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lung Neoplasms, Multiple Pulmonary Nodules. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
To perform a meta-analysis of the diagnostic performance of MRI for the detection of pulmonary nodules, with use of CT as the reference standard. Materials and Methods PubMed, Embase, Scopus, and other databases were systematically searched for studies published from January 2000 to March 2023 evaluating the performance of MRI for diagnosis of lung nodules measuring 4 mm or larger, with CT as reference. Studies including micronodules, nodules without size stratification, or those from which data for contingency tables could not be extracted were excluded. Primary outcomes were the per-lesion sensitivity of MRI and the rate of false-positive nodules per patient (FPP). Subgroup analysis by size and meta-regression with other covariates were performed. The study protocol was registered in the International Prospective Register of Systematic Reviews, or PROSPERO (no. CRD42023437509).
Results
Ten studies met inclusion criteria (1354 patients and 2062 CT-detected nodules). Overall, per-lesion sensitivity of MRI for nodules measuring 4 mm or larger was 87.7% (95% CI: 81.1, 92.2), while the FPP rate was 12.4% (95% CI: 7.0, 21.1). Subgroup analyses demonstrated that MRI sensitivity was 98.5% (95% CI: 90.4, 99.8) for nodules measuring at least 8-10 mm and 80.5% (95% CI: 71.5, 87.1) for nodules less than 8 mm.
Conclusion
MRI demonstrated a good overall performance for detection of pulmonary nodules measuring 4 mm or larger and almost equal performance to CT for nodules measuring at least 8-10 mm, with a low rate of FPP. Systematic review registry no. CRD42023437509 Keywords: Lung Nodule, Lung Cancer, Lung Cancer Screening, MRI, CT Supplemental material is available for this article. © RSNA, 2024.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- From the Department of Radiology, Pontifícia Universidade Católica do Rio Grande do Sul, Av Ipiranga, 6681 - Partenon, Porto Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.); Department of Radiolo…
ORCID-Profile: César Campagnolo Cavion, Stephan Altmayer, Gabriele Carra Forte, Rubens Gabriel Feijó Andrade, Martina Zaguini Francisco, Capitulino Camargo
Zitieren
APA
Cavion, C. C., Altmayer, S., Forte, G. C., Feijó Andrade, R. G., Hochhegger, D. Q. D. R., Zaguini Francisco, M., Camargo, C., Patel, P., & Hochhegger, B. (2024). Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis. Radiology: Cardiothoracic Imaging. https://doi.org/10.1148/ryct.230241
Vancouver
Cavion CC, Altmayer S, Forte GC, Feijó Andrade RG, Hochhegger DQDR, Zaguini Francisco M, et al. Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis. Radiology: Cardiothoracic Imaging. 2024. doi:10.1148/ryct.230241
BibTeX
@article{Cavion2024,
author = {Cavion, César Campagnolo and Altmayer, Stephan and Forte, Gabriele Carra and Feijó Andrade, Rubens Gabriel and Hochhegger, Daniela Quinto Dos Reis and Zaguini Francisco, Martina and Camargo, Capitulino and Patel, Pratik and Hochhegger, Bruno},
title = {Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis},
journal = {Radiology: Cardiothoracic Imaging},
year = {2024},
doi = {10.1148/ryct.230241}
}
EUVIMED