Robotic-assisted pedicle screw placement achieves high accuracy and narrows the experience gap: a preclinical evaluation
Journal of Robotic Surgery · 01.06.2026 · 20 (1)
DOI: 10.1007/s11701-026-03513-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Robotic Surgery, online erschienen am 01.06.2026. Verfasst von Anna T Reza und 9 weiteren Autor:innen. Beteiligte Einrichtung: Stryker (United States), Kalamazoo, USA. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Pedicle Screws, Clinical Competence. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
To assess a robotic-assisted system versus open manual techniques to: (1) compare pedicle screw accuracy between fellows and attendings with and without robotic assistance, and (2) evaluate executed versus planned trajectory fidelity relative to prior reports. Robotic-assisted spine systems aim to improve the accuracy, reproducibility, and safety of pedicle screw placement. Limited evidence compares outcomes across differing surgeon experience levels. A total of 255 thoracolumbar pedicle screws were placed in synthetic torsos simulating adult degenerative anatomy. Four surgeons (two fellows, two attendings) each placed half their screws using open fluoroscopy-guided techniques and half using a minimally invasive percutaneous approach with the Mako Spine system and intraoperative CT-based planning. Postoperative CT and the Gertzbein-Robbins classification were used to assess accuracy. Optimal placement (Grade A), breach rates, and positional/angular deviation from planned trajectories were recorded. The robotic cohort achieved a higher rate of clinically acceptable screw placement compared with the manual cohort, although this difference was not statistically significant (124/127, 97.6% vs. 120/128, 93.8%; P = 0.223). Fellows and attendings both achieved high clinically acceptable screw placement rates using robotics (63/64, 98.4% vs. 61/63, 96.8%). Among fellows, robotic assistance increased optimal screw placement compared with the manual technique (53/64, 82.8% vs. 41/64, 64.1%; P < 0.05). Robotic screws demonstrated low mean deviations from planned trajectories (1.4 ± 0.9 mm positional, 1.7 ± 1.1° angular). The Mako Spine system enabled precise screw placement and narrowed performance gaps for less experienced surgeons. It shows promise as both training tool and means to standardize outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Stryker (United States), Kalamazoo, USA.
- Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, USA. mitchng77@gmail.com.
- Department of Orthopaedic Surgery, Maimonides Medical Center, Brooklyn, USA.
- The Robotic Spine Institute of Las Vegas, Allegiant Spine Institute, Las Vegas, USA.
- Stanford University, Stanford, USA.
- Virginia Mason Medical Center, Seattle, USA.
Zitieren
APA
Reza, A. T., Walper, M., Ng, M. K., Mastrokostas, P. G., Lee, A. S., de Oliveira, R. G., Poelstra, K. A., Ratliff, J. K., Sethi, R. K., & Mont, M. A. (2026). Robotic-assisted pedicle screw placement achieves high accuracy and narrows the experience gap: a preclinical evaluation. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03513-3
Vancouver
Reza AT, Walper M, Ng MK, Mastrokostas PG, Lee AS, de Oliveira RG, et al. Robotic-assisted pedicle screw placement achieves high accuracy and narrows the experience gap: a preclinical evaluation. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03513-3
BibTeX
@article{Reza2026,
author = {Reza, Anna T and Walper, Matthias and Ng, Mitchell K and Mastrokostas, Paul G and Lee, Andrew S and de Oliveira, Rafael G and Poelstra, Kornelis A and Ratliff, John K and Sethi, Rajiv K and Mont, Michael A},
title = {Robotic-assisted pedicle screw placement achieves high accuracy and narrows the experience gap: a preclinical evaluation},
journal = {Journal of Robotic Surgery},
year = {2026},
volume = {20},
number = {1},
doi = {10.1007/s11701-026-03513-3}
}
EUVIMED