Airo® navigation versus freehand fluoroscopy technique: A comparative study of accuracy and radiological exposure for thoracolumbar screws placement
Neurochirurgie · 2023-05 · 69 (3) · 101437
DOI: 10.1016/j.neuchi.2023.101437 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurochirurgie, 2023-05. Verfasst von L S Chatelain und 3 weiteren Autor:innen. Beteiligte Einrichtung: Fondation Rothschild, Department of Neurosurgery, 25-29, rue Manin, 75019 Paris, France. Electronic address: leonard.chatelain@gmail.com. Hauptthemen laut MEDLINE: Pedicle Screws, Surgery, Computer-Assisted, Robotic Surgical Procedures, Spinal Fusion. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: The aim was to compare the accuracy of freehand fluoroscopy and CT based navigation on thoracolumbar screws placement and their respective effects on radiological exposure to the patient. No previous study directly compared the Airo® navigation system to freehand technique. METHODS: In this monocentric retrospective study, 156 consecutive patients who underwent thoracolumbar spine surgery were included. Epidemiological data and surgical indications were noted. Heary classification was used for thoracic screws and Gertzbein-Robbins classification for lumbar screws. Radiological exposure was collected for each surgery. RESULTS: A total of 918 screws were implanted. We analyzed 725 lumbar screws (Airo® 287; freehand fluoroscopy 438) and 193 thoracic screws (Airo® 49; freehand fluoroscopy 144). Overall, lumbar screws accuracy (Gertzbein-Robbins grade A and B) was good in both groups (freehand fluoroscopy 91.3%; Airo® 97.6%; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Fondation Rothschild, Department of Neurosurgery, 25-29, rue Manin, 75019 Paris, France. Electronic address: leonard.chatelain@gmail.com.
- Fondation Rothschild, Department of Neurosurgery, 25-29, rue Manin, 75019 Paris, France.
- Fondation Rothschild, Department of Neurosurgery, 25-29, rue Manin, 75019 Paris, France; American Hospital of Paris, 55, boulevard du Château, 92200 Neuilly-sur-Seine, France.
Zitieren
APA
Chatelain, L. S., Kourilsky, A., Lot, G., & Rogers, A. (2023). Airo® navigation versus freehand fluoroscopy technique: A comparative study of accuracy and radiological exposure for thoracolumbar screws placement. Neurochirurgie, 69(3), 101437. https://doi.org/10.1016/j.neuchi.2023.101437
Vancouver
Chatelain LS, Kourilsky A, Lot G, Rogers A. Airo® navigation versus freehand fluoroscopy technique: A comparative study of accuracy and radiological exposure for thoracolumbar screws placement. Neurochirurgie. 2023;69(3):101437. doi:10.1016/j.neuchi.2023.101437
BibTeX
@article{Chatelain2023,
author = {Chatelain, L S and Kourilsky, A and Lot, G and Rogers, A},
title = {Airo® navigation versus freehand fluoroscopy technique: A comparative study of accuracy and radiological exposure for thoracolumbar screws placement},
journal = {Neurochirurgie},
year = {2023},
volume = {69},
number = {3},
pages = {101437},
doi = {10.1016/j.neuchi.2023.101437}
}