EUVIMEDEUVIMED entdecken
VergleichsstudieSystematische ÜbersichtOpen Access · CC BY 4.0

Comparative clinical performance of robotic-assisted systems in spinal deformity surgery: focus on perioperative outcomes and pedicle screw accuracy

Yu Liu, Ruoyan Wang, Guohang Shen, Junlei Liao, Bo Mu, Yupei Dai, Nurul Azira Ismail

Journal of Robotic Surgery · 13.04.2026 · 20 (1)

DOI: 10.1007/s11701-026-03410-9 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Robotic Surgery, online erschienen am 13.04.2026. Verfasst von Yu Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Surgery, Affiliated Hospital of North Sichuan Medical College (Wenhua Road Campus), No. 63, Wenhua Road, Shunqing District, N…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Pedicle Screws, Scoliosis. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University-Level Natural Science Project (Young Scholars Program), North Sichuan Medical College, Nanchong Philosophy and Social Sciences Research Planning Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To compare the clinical effectiveness and safety of the TiRobot and Mazor robotic systems in spinal deformity surgery, with additional stratified analyses based on deformity type, including adolescent idiopathic scoliosis (AIS) and adult degenerative scoliosis (ADS). PubMed, Embase, Web of Science, and the Cochrane Library were systematically searched for comparative studies published up to February 1, 2026. Subgroup analyses were prespecified according to robotic platform (TiRobot vs. Mazor) and deformity type (AIS vs. ADS). Perioperative outcomes, radiographic parameters, pedicle screw accuracy, and safety endpoints were quantitatively synthesized. Compared with conventional techniques, robotic-assisted surgery was associated with prolonged operative time (MD = 29.64 min, P < 0.01), significantly improved pedicle screw accuracy (OR = 6.51, P < 0.01), and reduced radiation exposure (MD = − 5.27, P < 0.01), while no significant differences were observed in blood loss, hospital stay, or Cobb angle correction. Platform-based subgroup analyses indicated that TiRobot was associated with reduced intraoperative blood loss and shorter hospitalization, whereas Mazor demonstrated greater improvements in thoracic kyphosis and MT values. Disease-based subgroup analyses showed that operative time remained significantly longer in the AIS subgroup, whereas a shorter length of hospital stay was observed in ADS patients. No significant differences were detected in other outcomes across disease subtypes. Robotic assistance enhances pedicle screw accuracy and reduces radiation exposure. Both platform-specific and disease-specific differences exist in perioperative and radiographic outcomes, highlighting the importance of individualized surgical strategy based on both robotic system and deformity type.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresPedicle ScrewsScoliosisHumansOperative TimeTreatment OutcomeLength of StayAdolescent

Stichwörter der Autor:innen

Mazor robotic systemMeta-analysisRobot-assisted surgerySpinal deformitySystematic reviewTiRobot

Autor:innen und Institutionen

  • Department of Pediatric Surgery, Affiliated Hospital of North Sichuan Medical College (Wenhua Road Campus), No. 63, Wenhua Road, Shunqing District, Nanchong City, 637000, Sichuan Province, P.R. China.
  • School of Graduate Studies Post Groduate Centre, Management and Science University (MSU), University Drive, Off Persiaran Olahraga, Section 13, Shah Alam, Selangor, Malaysia.
  • School of Basic Medicine and Forensic Medicine, North Sichuan Medical College, No.234 Fujiang Road, Shunqing District, Nanchong, 637000, Sichuan, China.
  • Health Management Center of Affiliated Hospital of North Sichuan Medical College, Shunqing District, Nanchong City, 617000, Sichuan Province, P.R. China.
  • Department of Clinical Medicine, Ningxia Medical University, Yinchuan, 750004, Ningxia Hui Autonomous Region, PR China.
  • Department of Pediatric Surgery, Affiliated Hospital of North Sichuan Medical College (Wenhua Road Campus), No. 63, Wenhua Road, Shunqing District, Nanchong City, 637000, Sichuan Province, P.R. China. 1428421664@qq.com.

Förderung

  • University-Level Natural Science Project (Young Scholars Program), North Sichuan Medical College
  • Nanchong Philosophy and Social Sciences Research Planning Project

Zitieren

APA

Liu, Y., Wang, R., Shen, G., Liao, J., Mu, B., Dai, Y., & Ismail, N. A. (2026). Comparative clinical performance of robotic-assisted systems in spinal deformity surgery: focus on perioperative outcomes and pedicle screw accuracy. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03410-9

Vancouver

Liu Y, Wang R, Shen G, Liao J, Mu B, Dai Y, et al. Comparative clinical performance of robotic-assisted systems in spinal deformity surgery: focus on perioperative outcomes and pedicle screw accuracy. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03410-9

BibTeX
@article{Liu2026,
  author = {Liu, Yu and Wang, Ruoyan and Shen, Guohang and Liao, Junlei and Mu, Bo and Dai, Yupei and Ismail, Nurul Azira},
  title = {Comparative clinical performance of robotic-assisted systems in spinal deformity surgery: focus on perioperative outcomes and pedicle screw accuracy},
  journal = {Journal of Robotic Surgery},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1007/s11701-026-03410-9}
}
Kostenlos starten →