Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: a Meta-analysis
BMC Musculoskeletal Disorders · 2024
DOI: 10.1186/s12891-024-08088-4 ↗Kurz gefasst
Metaanalyse in der Zeitschrift BMC Musculoskeletal Disorders, 2024. Verfasst von Yifan Kang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral Candidate, The Fifth Clinical Medical College of Shanxi Medical University, Shanxi Provincial People's Hospital, Taiyuan, 030001, China. Hauptthemen laut MEDLINE: Scoliosis, Pedicle Screws, Robotic Surgical Procedures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: the Central Government Guide Local Science and Technology Development Fund Project.
Abstract (Originalsprache)
AIM: To investigate the safety and accuracy of robot-assisted pedicle screw placement in adolescent idiopathic scoliosis (AIS) surgery. METHODS: PubMed, Medline, Embase, Cochrane Library, Web of Science, CNKI, and EMCC databases were searched for studies utilizing the clinical data of adolescent idiopathic scoliosis patients (robot-assisted and fluoroscopy-assisted group) who underwent posterior pedicle screw fixation to collect preoperative, postoperative and follow-up indexes and imaging parameters, including screw implantation accuracy, the number of intraoperative fluoroscopy times, amount of bleeding, operation time, postoperative VAS score and postoperative Cobb angle. RESULTS: Six studies were included in this meta-analysis, including 154 patients in the intervention group and 171 patients in the control group. Our results showed that screw implantation accuracy (WMD 1.07, 95% CI (1.01,1.14), P = 0.03) was higher than that in the control group. The number of intraoperative fluoroscopy times (WMD -6.11, 95% CI (-9.60, -2.62), P = 0.0006) and operation time (WMD 31.52, 95% CI (5.70,57.35), P = 0.02) in the robot group were less, and the differences were statistically significant. Intraoperative blood (WMD -59.05, 95% CI (-212.81,94.70), P = 0.45), postoperative VAS score (WMD -0.07, 95% CI (-0.24,0.11), P = 0.46), preoperative Cobb angle (WMD 0.79, 95% CI (-1.12,2.69), P = 0.42) (Fig. 7), postoperative Cobb angle (WMD -0.25, 95% CI (-1.12,0.62), P = 0.57) (Fig. 8) had no statistical significance in the robot group compared with control group. CONCLUSION: The robot navigation system can improve screw implantation accuracy and reduce the operation time and radiation exposure during the operation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Doctoral Candidate, The Fifth Clinical Medical College of Shanxi Medical University, Shanxi Provincial People's Hospital, Taiyuan, 030001, China.
- Xiongan Xuanwu Hospital, Xiongan New Area, China.
- Doctoral Candidate, The Fifth Clinical Medical College of Shanxi Medical University, Shanxi Provincial People's Hospital, Taiyuan, 030001, China. liujianrong3@sina.com.
- Shanxi Provincial People's Hospital, Taiyuan, 030001, China. liujianrong3@sina.com.
Förderung
- the Central Government Guide Local Science and Technology Development Fund Project
Zitieren
APA
Kang, Y., Wei, L., & Liu, J. (2024). Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: a Meta-analysis. BMC Musculoskeletal Disorders. https://doi.org/10.1186/s12891-024-08088-4
Vancouver
Kang Y, Wei L, Liu J. Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: a Meta-analysis. BMC Musculoskeletal Disorders. 2024. doi:10.1186/s12891-024-08088-4
BibTeX
@article{Kang2024,
author = {Kang, Yifan and Wei, Lindong and Liu, Jianrong},
title = {Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: a Meta-analysis},
journal = {BMC Musculoskeletal Disorders},
year = {2024},
doi = {10.1186/s12891-024-08088-4}
}
EUVIMED