Evaluation of screw density in Lenke type 1 adolescent idiopathic scoliosis: are low and high-density constructs truly comparable?
European Journal of Orthopaedic Surgery & Traumatology · 2025
DOI: 10.1007/s00590-025-04545-5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2025. Verfasst von Leonardo Oggiano und 9 weiteren Autor:innen. Beteiligte Einrichtung: , Rome, Italy. Hauptthemen laut MEDLINE: Scoliosis, Bone Screws, Spinal Fusion. Die Arbeit nennt 43 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Adolescent idiopathic scoliosis (AIS) affects 3% of adolescents, with Lenke 1 curves comprising 40% of cases. All-screw (AS) constructs provide adequate curve correction and maintenance in the coronal plane. Low-density (LD) screw constructs may offer comparable deformity correction, reduced implant density, and lower costs compared to high-density (HD) constructs. This study compares LD and HD screw constructs in Lenke 1 AIS, analyzing radiographic and surgical outcomes. METHODS: The study included 86 pediatric patients with Lenke 1 AIS curves (Cobb angle 0.05). No significant differences were found in the loss of coronal correction or LOS. LD constructs resulted in shorter surgery durations (238 ± 5.1 vs. 255.9 ± 31.3 min, p < 0.05), less blood loss (470.2 ± 198.4 vs. 600.3 ± 263.5 mL, p < 0.05) and lower total cost of the implants (7460.6 ± 757.3€ vs. 8891.9 ± 783.8€, p < 0.05). The LD group had higher perioperative complications (8.1% vs. 2.7%) and major complications. CONCLUSIONS: No significant differences were observed in post-operative and last follow-up coronal and sagittal correction. The LD group demonstrated reduced blood loss, shorter operative times, and lower implant costs, albeit with a higher incidence of perioperative complications. Future studies should explore implant distribution, rather than implant density, to ultimately optimize postoperative outcomes in the treatment of Lenke 1 AIS curves.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- , Rome, Italy.
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128, Rome, Italy. paolo.brigato@outlook.it.
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128, Rome, Italy.
- Department of Pediatric Neurosurgery, Fondazione Policlinico Agostino Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00168, Rome, Italy.
- Department of Statistical Sciences, Sapienza University of Rome, Rome, Italy.
- Orthopedics and Traumatology Unit, Department of Geriatrics, Neurosciences and Orthopedics, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
Zitieren
APA
Oggiano, L., Brigato, P., De Salvatore, S., Palombi, D., Sangiovanni, G. M., Sessa, S., Fumo, C., Cruciani, A., Ruzzini, L., & Costici, P. F. (2025). Evaluation of screw density in Lenke type 1 adolescent idiopathic scoliosis: are low and high-density constructs truly comparable?. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-025-04545-5
Vancouver
Oggiano L, Brigato P, De Salvatore S, Palombi D, Sangiovanni GM, Sessa S, et al. Evaluation of screw density in Lenke type 1 adolescent idiopathic scoliosis: are low and high-density constructs truly comparable?. European Journal of Orthopaedic Surgery & Traumatology. 2025. doi:10.1007/s00590-025-04545-5
BibTeX
@article{Oggiano2025,
author = {Oggiano, Leonardo and Brigato, Paolo and De Salvatore, Sergio and Palombi, Davide and Sangiovanni, Gian Mario and Sessa, Sergio and Fumo, Caterina and Cruciani, Andrea and Ruzzini, Laura and Costici, Pier Francesco},
title = {Evaluation of screw density in Lenke type 1 adolescent idiopathic scoliosis: are low and high-density constructs truly comparable?},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2025},
doi = {10.1007/s00590-025-04545-5}
}
EUVIMED