IRE made easy: introducing the robotic grid system for multiple parallel needle insertion in irreversible electroporation treatment
International Journal of Computer Assisted Radiology and Surgery · 2024
DOI: 10.1007/s11548-024-03216-w ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Girindra Wardhana und 2 weiteren Autor:innen. Beteiligte Einrichtung: Robotics and Mechatronics Lab (RAM), TechMed Centre, University of Twente, Hallenweg 15, Enschede, 7500 NH, Overijssel, The Netherlands. g.wardhana@u…. Hauptthemen laut MEDLINE: Electroporation, Needles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Accurate needle placement is crucial for successful tumor treatment using the irreversible electroporation (IRE) method. Multiple needles are inserted around the tumor, ideally in parallel, to achieve uniform electric field distribution. This paper presents a robot utilizing a grid system to enable multiple needles insertion while maintaining parallelism between them.
Methods
The robotic system has two degrees of freedom, which allow for the adjustment of the grid system to accommodate targeting lesions in various positions. The robot’s performance was evaluated by testing its accuracy across various configurations and target depth locations, as well as its ability to maintain the needle parallelism.
Results
The robot has dimensions of $${\phi }$$ ϕ 134 mm and a height of 46 mm, with a total weight of 295 g. The system accuracy test showed that the robot can precisely target points across different target depths and needle orientations, with an average error of $$2.71\pm 0.68$$ 2.71 ± 0.68 mm. Moreover, multiple insertions at different grid locations reveal needle orientation deviations typically below $$1^{\circ }$$ 1 ∘ .
Conclusion
This study presented the design and validation of a robotic grid system. The robot is capable of maintaining insertion accuracy and needle parallelism during multiple needle insertions at various robot configurations. The robot showed promising results with limited needle deviation, making it suitable for IRE procedures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Robotics and Mechatronics Lab (RAM), TechMed Centre, University of Twente, Hallenweg 15, Enschede, 7500 NH, Overijssel, The Netherlands. g.wardhana@utwente.nl.
- Robotics and Mechatronics Lab (RAM), TechMed Centre, University of Twente, Hallenweg 15, Enschede, 7500 NH, Overijssel, The Netherlands.
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, Gelderland, The Netherlands.
Zitieren
APA
Wardhana, G., Fütterer, J. J., & Abayazid, M. (2024). IRE made easy: introducing the robotic grid system for multiple parallel needle insertion in irreversible electroporation treatment. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03216-w
Vancouver
Wardhana G, Fütterer JJ, Abayazid M. IRE made easy: introducing the robotic grid system for multiple parallel needle insertion in irreversible electroporation treatment. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03216-w
BibTeX
@article{Wardhana2024,
author = {Wardhana, Girindra and Fütterer, Jurgen J and Abayazid, Momen},
title = {IRE made easy: introducing the robotic grid system for multiple parallel needle insertion in irreversible electroporation treatment},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
doi = {10.1007/s11548-024-03216-w}
}
EUVIMED