EUVIMEDEUVIMED entdecken
Crossref

Variable Admittance Control of Symmetric Teleoperated System for Percutaneous Surgery With Reliable Interaction Force Perception

Hongbing Li iD, Linlong Li, Zhizhen Cai, Rui Wang, Evgeni Magid iD

The International Journal of Medical Robotics and Computer Assisted Surgery · 2026

DOI: 10.1002/rcs.70243 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2026. Verfasst von Hongbing Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Technology Breakthrough Plan Project of Science and Innovation Yongjiang 2035, Joint Fund of Scientific Research for the Public Hospitals of Inner Mongolia Academy of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Teleoperated percutaneous surgery offers significant clinical value by improving needle targeting accuracy and minimising radiation exposure to surgeons. Intuitive control and precise force perception in such teleoperated needle insertion robotic systems are critical for optimising curative effects and ensuring patient safety.

Methods

In this study, we propose a symmetric master–slave robotic system integrated with an adaptive variable admittance approach to provide an intuitive human‐robot interaction. A new variable admittance control algorithm for a symmetric teleoperation system is proposed to guarantee the reliable interaction force perception during constrained percutaneous operation.

Results

The intuitive human‐robot interaction is achieved by an adaptive variable admittance scheme that utilises the time derivative of the human applied force to assess human intentions.

Conclusions

The proposed control scheme enables smoother and higher precision master slave robot movement, thereby enhancing operational safety and procedural reliability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresSurgery, Computer-AssistedHumansAlgorithmsEquipment DesignReproducibility of ResultsNeedlesRoboticsMan-Machine SystemsTelemedicine

Stichwörter der Autor:innen

force perceptionsymmetric robotic systemteleoperationvariable admittance control

Autor:innen und Institutionen

  • School of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai, China.
  • Department of Cardiology, Inner Mongolia People's Hospital, Hohhot, China.
  • Institute of Information Technology and Intelligent Systems, Kazan Federal University, Kazan, Russia.

ORCID-Profile: Hongbing Li, Evgeni Magid

Förderung

  • National Natural Science Foundation of China
  • Key Technology Breakthrough Plan Project of Science and Innovation Yongjiang 2035
  • Joint Fund of Scientific Research for the Public Hospitals of Inner Mongolia Academy of Medical Sciences
  • Key R&D and Achievement Transformation Plan of the Inner Mongolia Autonomous Region Science and Technology Department

Zitieren

APA

Li, H., Li, L., Cai, Z., Wang, R., & Magid, E. (2026). Variable Admittance Control of Symmetric Teleoperated System for Percutaneous Surgery With Reliable Interaction Force Perception. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70243

Vancouver

Li H, Li L, Cai Z, Wang R, Magid E. Variable Admittance Control of Symmetric Teleoperated System for Percutaneous Surgery With Reliable Interaction Force Perception. The International Journal of Medical Robotics and Computer Assisted Surgery. 2026. doi:10.1002/rcs.70243

BibTeX
@article{Li2026,
  author = {Li, Hongbing and Li, Linlong and Cai, Zhizhen and Wang, Rui and Magid, Evgeni},
  title = {Variable Admittance Control of Symmetric Teleoperated System for Percutaneous Surgery With Reliable Interaction Force Perception},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2026},
  doi = {10.1002/rcs.70243}
}
Kostenlos starten →