Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array
Journal of Nondestructive Evaluation · 2024-09 · 43 (3)
DOI: 10.1007/s10921-024-01113-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nondestructive Evaluation, online erschienen am 14.08.2024. Verfasst von Haruki Hattori und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
X-ray cone-beam computed tomography (CBCT) is a powerful tool for nondestructive testing and evaluation, yet the CT image quality can be compromised by artifact due to X-ray scattering within dense materials such as metals. This problem leads to the need for hardware- and software-based scatter artifact correction to enhance the image quality. Recently, deep learning techniques have merged as a promising approach to obtain scatter-free images efficiently. However, these deep learning techniques rely heavily on training data, often gathered through simulation. Simulated CT images, unfortunately, do not accurately reproduce the real properties of objects, and physically accurate X-ray simulation still requires significant computation time, hindering the collection of a large number of CT images. To address these problems, we propose a deep learning framework for scatter artifact correction using projections obtained solely by real CT scanning. To this end, we utilize a beam-hole array (BHA) to block the X-rays deviating from the primary beam path, thereby capturing scatter-free X-ray intensity at certain detector pixels. As the BHA shadows a large portion of detector pixels, we incorporate several regularization losses to enhance the training process. Furthermore, we introduce radiographic data augmentation to mitigate the need for long scanning time, which is a concern as CT devices equipped with BHA require two series of CT scans. Experimental validation showed that the proposed framework outperforms a baseline method that learns simulated projections where the entire image is visible and does not contain scattering artifacts.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Hattori, H., Yatagawa, T., Ohtake, Y., & Suzuki, H. (2024). Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array. Journal of Nondestructive Evaluation, 43(3). https://doi.org/10.1007/s10921-024-01113-5
Vancouver
Hattori H, Yatagawa T, Ohtake Y, Suzuki H. Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array. Journal of Nondestructive Evaluation. 2024;43(3). doi:10.1007/s10921-024-01113-5
BibTeX
@article{Hattori2024,
author = {Hattori, Haruki and Yatagawa, Tatsuya and Ohtake, Yutaka and Suzuki, Hiromasa},
title = {Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array},
journal = {Journal of Nondestructive Evaluation},
year = {2024},
volume = {43},
number = {3},
doi = {10.1007/s10921-024-01113-5}
}
EUVIMED