EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparative performance of open thorax epicardial linear cryoprobe ablation versus focal tip radiofrequency catheter ablation in ventricular scar

Justin Hayase, Rami Aladham, Min Zhang, Gregory A Fishbein, Takanori Sato, Shumpei Mori, Kalyanam Shivkumar, Olujimi A Ajijola, Jason S Bradfield

Journal of Interventional Cardiac Electrophysiology · 24.07.2026 · 69 (8) · 2549-2555

DOI: 10.1007/s10840-026-02412-9 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 24.07.2026. Verfasst von Justin Hayase und 8 weiteren Autor:innen. Beteiligte Einrichtung: UCLA Cardiac Electrophysiology Division, Ronald Reagan UCLA Medical Center, Los Angeles, CA, USA. justin.hayase@gmail.com. Hauptthemen laut MEDLINE: Cryosurgery, Cicatrix, Catheter Ablation, Pericardium. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AtriCure.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Epicardial cryoablation is increasingly utilized in open surgical procedures for treatment of ventricular arrhythmias in patients with structural heart disease when percutaneous epicardial access cannot be obtained. There are limited data regarding the effects of cryoablation within ventricular scar tissue, particularly in comparison to the performance of radiofrequency (RF) catheter ablation. This study aimed to investigate the comparative performance of ablation delivered epicardially in an open chest animal model with a linear cryoprobe versus a radiofrequency catheter.

Methods

An infarct model was created in five Yorkshire swine using microsphere injection into the left anterior descending artery. After 6–8 weeks, animals underwent median sternotomy with targeted epicardial RF ablation lesions, and linear cryoablation lesions were delivered to myocardial infarct scar regions. Specimens were pressure perfused with 10% formalin, and histological analysis was performed.

Results

Out of 25 epicardial RF lesions, 13 were visible and able to be analyzed. All 15 epicardial cryoablation lesions were visible. All 15 cryoablation lesions had transmural effect within scar where tissue thickness was ≤6 mm, whereas only 62% of evaluable RF lesions were transmural in scar ( p = 0.01). Average cryoablation lesion depth was 4.2 ± 1.1 mm in scar and 5.6 ± 1.4 mm in border zone.

Conclusion

Linear epicardial cryoablation is a useful tool in open surgical procedures to treat ventricular arrhythmias in structural heart disease. Cryoablation can achieve transmurality in tissue with ≤ 6 mm thickness with more technically reliable effect compared to catheter RF in the open chest.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CryosurgeryCicatrixCatheter AblationPericardiumHeart VentriclesMyocardial InfarctionAnimalsSwineTreatment OutcomeEquipment DesignEquipment Failure AnalysisDisease Models, Animal

Stichwörter der Autor:innen

Border zoneCatheter ablationCryoablationMyocardial scar

Autor:innen und Institutionen

  • UCLA Cardiac Electrophysiology Division, Ronald Reagan UCLA Medical Center, Los Angeles, CA, USA. justin.hayase@gmail.com.
  • UCLA Cardiac Electrophysiology Division, Ronald Reagan UCLA Medical Center, Los Angeles, CA, USA.
  • UCLA Department of Pathology, Ronald Reagan UCLA Medical Center, Los Angeles, CA, USA.

Förderung

  • AtriCure

Zitieren

APA

Hayase, J., Aladham, R., Zhang, M., Fishbein, G. A., Sato, T., Mori, S., Shivkumar, K., Ajijola, O. A., & Bradfield, J. S. (2026). Comparative performance of open thorax epicardial linear cryoprobe ablation versus focal tip radiofrequency catheter ablation in ventricular scar. Journal of Interventional Cardiac Electrophysiology, 69(8), 2549-2555. https://doi.org/10.1007/s10840-026-02412-9

Vancouver

Hayase J, Aladham R, Zhang M, Fishbein GA, Sato T, Mori S, et al. Comparative performance of open thorax epicardial linear cryoprobe ablation versus focal tip radiofrequency catheter ablation in ventricular scar. Journal of Interventional Cardiac Electrophysiology. 2026;69(8):2549-2555. doi:10.1007/s10840-026-02412-9

BibTeX
@article{Hayase2026,
  author = {Hayase, Justin and Aladham, Rami and Zhang, Min and Fishbein, Gregory A and Sato, Takanori and Mori, Shumpei and Shivkumar, Kalyanam and Ajijola, Olujimi A and Bradfield, Jason S},
  title = {Comparative performance of open thorax epicardial linear cryoprobe ablation versus focal tip radiofrequency catheter ablation in ventricular scar},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  volume = {69},
  number = {8},
  pages = {2549--2555},
  doi = {10.1007/s10840-026-02412-9}
}
Kostenlos starten →