EUVIMEDEUVIMED entdecken
Open Access

High predictive value of paced QRS frequency in verification of left bundle branch pacing

Ramya Vajapey, Ram Amuthan, Mina Chung, Patrick Tchou, John Rickard, Roy Chung, Niraj Varma, Mark Niebauer

Journal of Interventional Cardiac Electrophysiology · 2023

DOI: 10.1007/s10840-023-01541-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2023. Verfasst von Ramya Vajapey und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cleveland Clinic Foundation, Cleveland, OH, 44195, USA. vajaper@ccf.org. Hauptthemen laut MEDLINE: Ventricular Septum, Cardiac Resynchronization Therapy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: BLRD VA, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Left bundle branch area pacing (LBBAP) is a newer technique to deliver more synchronous left ventricular activation. Several criteria have been proposed, but not fully validated, to confirm LBBAP during implantation of the pacing lead. Spectral analysis has been used to characterize the frequency components of the clinical QRS utilizing the Fourier transform algorithm. We hypothesized that higher frequency content of the paced QRS complex may show predictive value of successful LBBAP. METHODS: We evaluated 84 patients with ejection fraction > 50%, who underwent LBB lead placement (n = 42) using ≥ 1 current criteria and right ventricular midseptal (RVsp) lead placement (n = 42) from 2000 to 2022. Time frequency analysis (Matlab) was used to determine the frequency content of the paced QRS complex. The centroid frequency (CF), which is the weighted average QRS frequency, was calculated. RESULTS: Patients in RVsp group had a longer paced QRS duration (155.6 ± 28.0 vs 127.1 ± 17.2, p < 0.002) compared to the LBBAP group. Of all standard ECG leads, the paced QRS in V2 gave the greatest difference of the CF of the LBBAP group at 8.8 ± 1.6 Hz versus 5.7 ± 0.7 Hz of the RVsp group. This difference was significant by both univariate (p < 0.003) and multivariate (p < 0.010) analysis. Predictive value of the CF for successful LBB pacing in lead V2 was highest with an AUC of 0.98. The sensitivity and specificity were 88.1% and 97.6%, respectively. CONCLUSION: Spectral analysis predicts successful LBBAP with higher frequency content when compared to RVsp pacing. Given the limitations to the current criteria to confirm LBBAP, intraprocedural use of frequency content analysis of the paced QRS complex in patients may prove useful at verifying LBB capture if verified by prospective clinical trials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ventricular SeptumCardiac Resynchronization TherapyHumansCardiac Pacing, ArtificialProspective StudiesTreatment OutcomeHeart Conduction SystemElectrocardiographyBundle of His

Stichwörter der Autor:innen

Centroid frequencyCriteriaLeft bundle branchLeft bundle pacingResynchronization therapyRight ventricular septal pacingSpectral analysis

Autor:innen und Institutionen

  • Cleveland Clinic Foundation, Cleveland, OH, 44195, USA. vajaper@ccf.org.
  • Case Western Reserve University, Cleveland, OH, 44106, USA.
  • Cleveland Clinic Foundation, Cleveland, OH, 44195, USA.

Förderung

  • BLRD VA
  • NHLBI NIH HHS

Zitieren

APA

Vajapey, R., Amuthan, R., Chung, M., Tchou, P., Rickard, J., Chung, R., Varma, N., & Niebauer, M. (2023). High predictive value of paced QRS frequency in verification of left bundle branch pacing. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-023-01541-9

Vancouver

Vajapey R, Amuthan R, Chung M, Tchou P, Rickard J, Chung R, et al. High predictive value of paced QRS frequency in verification of left bundle branch pacing. Journal of Interventional Cardiac Electrophysiology. 2023. doi:10.1007/s10840-023-01541-9

BibTeX
@article{Vajapey2023,
  author = {Vajapey, Ramya and Amuthan, Ram and Chung, Mina and Tchou, Patrick and Rickard, John and Chung, Roy and Varma, Niraj and Niebauer, Mark},
  title = {High predictive value of paced QRS frequency in verification of left bundle branch pacing},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2023},
  doi = {10.1007/s10840-023-01541-9}
}
Kostenlos starten →