EUVIMEDEUVIMED entdecken
Crossref

Does the use of intracardiac echocardiography during atrial fibrillation catheter ablation improve outcomes and cost? A nationwide 14-year analysis from 2001 to 2014

Ameesh Isath, Deepak Padmanabhan, Syed Waqas Haider, Gregory Siroky, Stuthi Perimbeti, Ashish Correa, C Anwar A Chahal, Jayaprakash Shenthar, Samuel Asirvatham, Davendra Mehta

Journal of Interventional Cardiac Electrophysiology · 2021-09 · 61 (3) · 461-468

DOI: 10.1007/s10840-020-00844-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 02.08.2020. Verfasst von Ameesh Isath und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Mount Sinai St. Luke's and Mount Sinai West, New York, NY, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Heart Diseases. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Intracardiac echocardiography (ICE) use during catheter ablation of atrial fibrillation (AF) provides real-time information to guide transseptal access, for monitoring the ablation and recognition of pericardial bleed. We describe trends of ICE use, impact on complications, and its in-hospital outcomes. METHODS: The national in-patient sample database was queried from 2001 to 2014 for diagnosis of AF based on ICD-9-CM 427.31 with a catheter ablation procedure code (37.34) in the same hospitalization and its associated complications. ICE was identified using ICD-9-CM procedure code (37.28). Statistical Analysis System (SAS) was used for analysis. RESULTS: There was an estimated total 299,152 patients who underwent AF ablation from 2001 to 2014 of which ICE was used in 46,688 (15.6%) patients. The use of ICE significantly increased from 0.08% in 2001 to 15.7% in 2014. In-hospital mortality was significantly lower in patients in whom ICE was used (0.11% vs 0.54%, p < 0.0001). Complications were 52% lower in procedures using ICE vs without ICE (HR [95%CI]; 0.48 [0.44-0.51]). The rate of cardiac complications was also lower in ICE users (3.67% vs 4.51%; p = 0.025). The use of ICE during AF ablation resulted in significantly higher cost of hospitalization ($98,436 ± 597 vs $81,300 ± 310; p < 0.0001), but this was offset by a decreased length of hospital stay (2.1 ± 0.02 vs 4 ± 0.02 days; p < 0.0001). CONCLUSIONS: The use of ICE during AF ablation has increased over the years and is associated with lower in-hospital mortality and procedural complications, shorter LOS but an increased cost of hospitalization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationHeart DiseasesEchocardiographyHumansTreatment Outcome

Stichwörter der Autor:innen

Atrial fibrillationCatheter ablationComplicationsCost-effectivenessIntracardiac echocardiography

Autor:innen und Institutionen

  • Department of Medicine, Mount Sinai St. Luke's and Mount Sinai West, New York, NY, USA.
  • Department of Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bengaluru, Karnataka, India.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, NY, USA.
  • Department of Cardiology, Mount Sinai St. Luke's, Mount Sinai Morning Side - West Hospital, 1111 Amsterdam Ave, New York City, NY, 10025, USA.
  • Department of Cardiology, University of Pennsylvania, Philadelphia, PA, USA.
  • Department of Cardiology, Mount Sinai St. Luke's, Mount Sinai Morning Side - West Hospital, 1111 Amsterdam Ave, New York City, NY, 10025, USA. davendra.mehta@mountsinai.org.

Zitieren

APA

Isath, A., Padmanabhan, D., Haider, S. W., Siroky, G., Perimbeti, S., Correa, A., Chahal, C. A. A., Shenthar, J., Asirvatham, S., & Mehta, D. (2021). Does the use of intracardiac echocardiography during atrial fibrillation catheter ablation improve outcomes and cost? A nationwide 14-year analysis from 2001 to 2014. Journal of Interventional Cardiac Electrophysiology, 61(3), 461-468. https://doi.org/10.1007/s10840-020-00844-5

Vancouver

Isath A, Padmanabhan D, Haider SW, Siroky G, Perimbeti S, Correa A, et al. Does the use of intracardiac echocardiography during atrial fibrillation catheter ablation improve outcomes and cost? A nationwide 14-year analysis from 2001 to 2014. Journal of Interventional Cardiac Electrophysiology. 2021;61(3):461-468. doi:10.1007/s10840-020-00844-5

BibTeX
@article{Isath2021,
  author = {Isath, Ameesh and Padmanabhan, Deepak and Haider, Syed Waqas and Siroky, Gregory and Perimbeti, Stuthi and Correa, Ashish and Chahal, C Anwar A and Shenthar, Jayaprakash and Asirvatham, Samuel and Mehta, Davendra},
  title = {Does the use of intracardiac echocardiography during atrial fibrillation catheter ablation improve outcomes and cost? A nationwide 14-year analysis from 2001 to 2014},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2021},
  volume = {61},
  number = {3},
  pages = {461--468},
  doi = {10.1007/s10840-020-00844-5}
}
Kostenlos starten →