EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY-NC 4.0

Safety and efficacy of intracardiac echocardiography–guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trial

Jinhee Ahn iD, Dong Geum Shin iD, Sang-Jin Han iD, Hong Euy Lim iD

Europace · 19.05.2023 · 25 (5)

DOI: 10.1093/europace/euad086 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Europace, online erschienen am 06.04.2023. Verfasst von Jinhee Ahn und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Internal Medicine, Pusan National University Hospital, 14068 Busan, Gyeonggi-do, Republic of Korea. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Cryosurgery. Die Arbeit wurde bisher 54-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Pusan National University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The development of intracardiac echocardiography (ICE) has enabled fluoroless atrial fibrillation (AF) ablation using three-dimensional electroanatomical mapping systems. However, fluoroless cryoballoon ablation (CBA) remains challenging, mainly because of the lack of a visual mapping system. Hence, this study aimed to investigate the safety and efficacy of fluoroless CBA for AF under ICE guidance. Methods and results Patients (n = 100) who underwent CBA for paroxysmal AF were randomly assigned to zero-fluoroscopic (Zero-X) and conventional groups. Intracardiac echocardiography was used to guide the transseptal puncture and catheter and balloon manipulation in all enrolled patients. The patients were prospectively followed for 12 months after CBA. The mean age was 60.4 years, and the left atrial (LA) size was 39.4 mm. Pulmonary vein isolation (PVI) was achieved in all patients. In the Zero-X group, fluoroscopy was used in only one patient because of unstable phrenic nerve capture during right-sided PVI. The procedure time and LA indwelling time in the Zero-X group were not statistically different compared with that in the conventional group. Fluoroscopic time (9.0 vs. 0.008 min) and radiation exposure (29.4 vs. 0.02 mGy) were significantly shorter in the Zero-X group than in the conventional group (P < 0.001). The complication rate did not differ between the two groups. During a mean follow-up of 663.3 ± 172.3 days, the recurrence rate was similar (16.0 vs. 18.0%; P = 0.841) between the groups. Multivariate analysis revealed that LA size was the only independent predictor of clinical recurrence.

Conclusion

Intracardiac echocardiography–guided fluoroless CBA for AF was a feasible strategy without compromising acute and long-term success or complication rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationPulmonary VeinsCryosurgeryHumansMiddle AgedProspective StudiesTreatment OutcomeFluoroscopyEchocardiography

Stichwörter der Autor:innen

Atrial fibrillationCryoballoon ablationIntracardiac echocardiographyRadiation exposure

Autor:innen und Institutionen

  • Division of Cardiology, Department of Internal Medicine, Pusan National University Hospital, 14068 Busan, Gyeonggi-do, Republic of Korea.
  • Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.
  • Division of Cardiology, Hallym University Kangnam Sacred Heart Hospital, Seoul, Republic of Korea.
  • Division of Cardiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, 22, Gwanpyeong-ro 170beon-gil, Dongan-gu, Anyang-si 14068, Gyeonggi-do, Republic of Korea.

ORCID-Profile: Jinhee Ahn, Dong Geum Shin, Sang-Jin Han, Hong Euy Lim

Förderung

  • Pusan National University Hospital

Zitieren

APA

Ahn, J., Shin, D. G., Han, S. J., & Lim, H. E. (2023). Safety and efficacy of intracardiac echocardiography–guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trial. Europace, 25(5). https://doi.org/10.1093/europace/euad086

Vancouver

Ahn J, Shin DG, Han SJ, Lim HE. Safety and efficacy of intracardiac echocardiography–guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trial. Europace. 2023;25(5). doi:10.1093/europace/euad086

BibTeX
@article{Ahn2023,
  author = {Ahn, Jinhee and Shin, Dong Geum and Han, Sang-Jin and Lim, Hong Euy},
  title = {Safety and efficacy of intracardiac echocardiography–guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trial},
  journal = {Europace},
  year = {2023},
  volume = {25},
  number = {5},
  doi = {10.1093/europace/euad086}
}
Kostenlos starten →