EUVIMEDEUVIMED entdecken
Crossref

Impact of pre‐ablation left appendage flow velocities on long term recurrence of catheter ablation for paroxysmal atrial fibrillation

Jing Cui iD, Xin Du, Liu He, Shi-Jun Xia, Ri-Bo Tang iD, Cai-Hua Sang iD, De-Yong Long, Jian-Zeng Dong iD, Chang-Sheng Ma iD

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14828 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2023. Verfasst von Jing Cui und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijin…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Atrial Appendage, Catheter Ablation. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Despite undergoing a single ablation, many patients with paroxysmal atrial fibrillation (PAF) experience a gradually increasing recurrence rate. This study aims to examine the relationship between left atrial appendage emptying velocity (LAAeV) and filling velocity (LAAfV) profiles and 3‐year recurrence of AF after ablation.

Methods

We conducted a prospective study of 658 consecutive PAF patients who underwent their first ablation between January 2018 and December 2019. We collected the clinical and echocardiographic characteristics of the patients. LAAeV and LAAfV were obtained from a transesophageal echocardiogram (TEE) before catheter ablation. Patients were followed at regular intervals to monitor for the primary outcome of AF recurrence.

Results

After a median follow‐up period of 35.3 months (range, 10.7–36.3), 288 patients (43.8%) experienced AF recurrence after catheter ablation. Patients who experienced AF recurrence had decreased LAAeV and LAAfV (LAAeV: 56.5 ± 21.2 vs. 59.6 ± 20.7 cm/s, p = .052; LAAfV: 47.5 ± 17.9 vs. 51.7 ± 18.2, p = .003). Kaplan–Meier analysis showed that patients in the low LAAeV (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationAtrial AppendageCatheter AblationHumansProspective StudiesEchocardiographyRecurrenceTreatment Outcome

Stichwörter der Autor:innen

atrial fibrillationcatheter ablationleft atrial appendage velocityrecurrence

Autor:innen und Institutionen

  • Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China.

ORCID-Profile: Jing Cui, Ri-Bo Tang, Cai-Hua Sang, Jian-Zeng Dong, Chang-Sheng Ma

Zitieren

APA

Cui, J., Du, X., He, L., Xia, S. J., Tang, R. B., Sang, C. H., Long, D. Y., Dong, J. Z., & Ma, C. S. (2023). Impact of pre‐ablation left appendage flow velocities on long term recurrence of catheter ablation for paroxysmal atrial fibrillation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14828

Vancouver

Cui J, Du X, He L, Xia SJ, Tang RB, Sang CH, et al. Impact of pre‐ablation left appendage flow velocities on long term recurrence of catheter ablation for paroxysmal atrial fibrillation. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14828

BibTeX
@article{Cui2023,
  author = {Cui, Jing and Du, Xin and He, Liu and Xia, Shi-Jun and Tang, Ri-Bo and Sang, Cai-Hua and Long, De-Yong and Dong, Jian-Zeng and Ma, Chang-Sheng},
  title = {Impact of pre‐ablation left appendage flow velocities on long term recurrence of catheter ablation for paroxysmal atrial fibrillation},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14828}
}
Kostenlos starten →