Factors associated with ocular prosthesis motility in anophthalmic patients: a multivariable analysis
International Ophthalmology · 10.11.2026 · 46 (1)
DOI: 10.1007/s10792-026-04320-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 10.11.2026. Verfasst von Yoav Vardizer und 2 weiteren Autor:innen. Beteiligte Einrichtung: The Ruth and Bruch Rappaport Faculty of Medicine, Technion ‑ Israel Institute of Technology, Haifa, Israel. Hauptthemen laut MEDLINE: Anophthalmos, Eye, Artificial, Eye Movements, Orbital Implants. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technion - Israel Institute of Technology.
Abstract (Originalsprache)
Purpose
To identify the clinical, anatomical, and prosthetic factors independently associated with ocular prosthesis motility in anophthalmic patients.
Methods
This prospective cross-sectional study included 107 patients with unilateral anophthalmia wearing acrylic prostheses. Horizontal prosthesis motility was graded relative to the fellow eye by three independent masked examiners using a five-point ordinal scale. Candidate predictors associated in univariate analysis (p ≤ 0.10) were entered into blockwise multivariable regression across five domains: clinical background, socket and eyelid findings, socket motility parameters, prosthesis primary gaze alignment, and prosthesis structural dimensions.
Results
Independent predictors of prosthesis motility were socket temporal motility (β = 0.36, p < 0.001), time since anophthalmia (β = –0.23, p = 0.003), prosthesis primary gaze alignment (β = 0.21, p = 0.002), socket downward motility (β = 0.20, p = 0.027), inferior fornix depth (β = 0.19, p = 0.007), and levator function (β = 0.15, p = 0.042), together explaining 67% of the variance in examiner-rated prosthesis motility (adjusted R 2 = 0.64). Prosthesis dimensions, demographic variables, and orbital implant status did not retain independent significance.
Conclusion
In this study, prosthesis motility was primarily associated with socket dynamics, structural socket capacity, eyelid function, and chronicity of anophthalmia. These findings highlight the importance of multifactorial clinical assessment when evaluating prosthetic eye movement as part of visual and cosmetic rehabilitation after eye loss.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Ruth and Bruch Rappaport Faculty of Medicine, Technion ‑ Israel Institute of Technology, Haifa, Israel.
- Department of Ophthalmology, Bnai Zion Medical Center, Haifa, Israel.
- Department of Ophthalmology, Carmel Medical Center, Haifa, Israel.
- The Ruth and Bruch Rappaport Faculty of Medicine, Technion ‑ Israel Institute of Technology, Haifa, Israel. yinonshapira@technion.ac.il.
- Department of Ophthalmology, Carmel Medical Center, Haifa, Israel. yinonshapira@technion.ac.il.
ORCID-Profile: Yinon Shapira
Förderung
- Technion - Israel Institute of Technology
Zitieren
APA
Vardizer, Y., Tomkins-Netzer, O., & Shapira, Y. (2026). Factors associated with ocular prosthesis motility in anophthalmic patients: a multivariable analysis. International Ophthalmology, 46(1). https://doi.org/10.1007/s10792-026-04320-3
Vancouver
Vardizer Y, Tomkins-Netzer O, Shapira Y. Factors associated with ocular prosthesis motility in anophthalmic patients: a multivariable analysis. International Ophthalmology. 2026;46(1). doi:10.1007/s10792-026-04320-3
BibTeX
@article{Vardizer2026,
author = {Vardizer, Yoav and Tomkins-Netzer, Oren and Shapira, Yinon},
title = {Factors associated with ocular prosthesis motility in anophthalmic patients: a multivariable analysis},
journal = {International Ophthalmology},
year = {2026},
volume = {46},
number = {1},
doi = {10.1007/s10792-026-04320-3}
}