Construction of a deep ocular prosthesis socket using a concave bowl-shaped composite graft from the conchal cymba
Journal of Plastic, Reconstructive & Aesthetic Surgery · 2025
DOI: 10.1016/j.bjps.2025.04.048 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2025. Verfasst von Kazuhiro Tsunekawa und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan. Electronic a…. Hauptthemen laut MEDLINE: Eye, Artificial, Plastic Surgery Procedures, Ear Cartilage. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: A deep socket is needed to wear an ocular prosthesis stably in patients with anophthalmia, hypophthalmia, or post-inflammatory fornix adhesions. This report introduces the novel approach of reconstructing a deep fornix using a composite graft from the conchal cymba. METHODS: Four patients who underwent construction of an inferior fornix by means of a composite graft obtained from the conchal cymba at Shinshu University Hospital between 2004 and 2024 were retrospectively studied. We analyzed graft size, postoperative outcomes, and complications. OPERATIVE TECHNIQUE: A composite graft from the conchal cymba was harvested in patients unable to wear an ocular prosthesis. The shallow inferior fornix was incised horizontally, and a vestibule for the composite graft was created by blunt dissection, taking care not to damage the septum. We drilled square holes of 1 × 1 mm into the cartilage side of the composite graft, which was then transplanted into the space created in the fornix and fixed with gauze. RESULTS: The composite graft survived in all 4 patients who underwent reconstruction of the inferior fornix using this technique. All patients were able to wear an ocular prosthesis stably and reported satisfaction with their aesthetic improvement at 6-27 months of follow-up. No major procedure-related adverse events were recorded. CONCLUSIONS: A deep concave vestibule was constructed in a single operation using a bowl-shaped composite graft obtained from the conchal cymba. This novel method may enable ocular prosthesis fitting by constructing a deep and stable socket.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan. Electronic address: tsune@shinshu-u.ac.jp.
- Department of Plastic and Reconstructive Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan.
Zitieren
APA
Tsunekawa, K., & Yuzuriha, S. (2025). Construction of a deep ocular prosthesis socket using a concave bowl-shaped composite graft from the conchal cymba. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2025.04.048
Vancouver
Tsunekawa K, Yuzuriha S. Construction of a deep ocular prosthesis socket using a concave bowl-shaped composite graft from the conchal cymba. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2025. doi:10.1016/j.bjps.2025.04.048
BibTeX
@article{Tsunekawa2025,
author = {Tsunekawa, Kazuhiro and Yuzuriha, Shunsuke},
title = {Construction of a deep ocular prosthesis socket using a concave bowl-shaped composite graft from the conchal cymba},
journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
year = {2025},
doi = {10.1016/j.bjps.2025.04.048}
}
EUVIMED