Standardized clinical evaluation of dry anophthalmic socket syndrome in a real-world approach
Contact Lens and Anterior Eye · 2024
DOI: 10.1016/j.clae.2024.102149 ↗Kurz gefasst
Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2024. Verfasst von Zamorano-Martín Francisco und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Hospital Regional Universitario de Málaga, Malaga, Spain; Deparment of Radiology and Physical Medicine, Ophthalmology an…. Hauptthemen laut MEDLINE: Eye, Artificial, Dry Eye Syndromes, Anophthalmos. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
PURPOSE: To assess which signs and eye prosthesis care habits are related to subjective discomfort in patients with dry anophthalmic socket syndrome (DASS), using standardized tools from daily practice. METHODS: 62 anophthalmic sockets were compared with their healthy fellow eye using the Standard Patient Evaluation of Eye Dryness (SPEED) score. The correlations between SPEED questionnaire and the prosthesis care, discharge characteristics score, conjunctival inflammation score, meibomian gland dysfunction (MGD) scores and Schirmer I test were studied. RESULT: The anophthalmic sockets group achieved a higher SPEED test score (p < 0.01), discharge score (p < 0.01), conjunctival inflammation score (p < 0.01), MGD scores (p < 0.01) and lower Schirmer I test (p < 0.01) compared with their fellow, healthy eye. Patients with a prosthesis replacement of one year or less, those with a current fit time of one year or less and those with a cleaning frequency above one month reported better SPEED, (p < 0.01), conjunctiva inflammation (p < 0.01) and MGD scores (p < 0.01). CONCLUSION: Most anophthalmic patients suffer mild to severe DASS, which seems related to discharge, conjunctival inflammation and MGD. Moreover, certain practices related to the care of the prosthesis such as replacing with a frequency lower than yearly, current fitting time inferior to one year and a removing and cleaning regime above one month, were related to a lower discomfort sensation, conjunctival inflammation and MGD. Clinicians should consider the DASS when facing patients with anophthalmic socket and discomfort symptoms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Hospital Regional Universitario de Málaga, Malaga, Spain; Deparment of Radiology and Physical Medicine, Ophthalmology and Otorhinolaryngology, Ophthalmology Area, Facultad de Medicina, Unive…
- Department of Ophthalmology, Hospital Clínic de Barcelona, Barcelona, Spain.
- Department of Physics of Condensed Matter, Optics Area, Universidad de Sevilla, Seville, Spain; Department of Ophthalmology (Tecnolaser Clinic Vision), Refractive Surgery Centre, Seville, Spain. Electronic address: jsan…
- Department of Ophthalmology, Hospital Regional Universitario de Málaga, Malaga, Spain.
- Department of Ophthalmology, Hospital Regional Universitario de Málaga, Malaga, Spain; Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, Almeria, Spain.
- Deparment of Radiology and Physical Medicine, Ophthalmology and Otorhinolaryngology, Ophthalmology Area, Facultad de Medicina, Universidad de Málaga, Malaga, Spain; Department of Ophthalmology, Hospital Universitario Vi…
Zitieren
APA
Francisco, Z. M., Sara, M. M., José-María, S. G., Facundo, U., Carlos, R. D., María, G. L., Jessica, M., Carmen, A. L., Santiago, O. P., & Juan Carlos, S. E. (2024). Standardized clinical evaluation of dry anophthalmic socket syndrome in a real-world approach. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2024.102149
Vancouver
Francisco ZM, Sara MM, José-María SG, Facundo U, Carlos RD, María GL, et al. Standardized clinical evaluation of dry anophthalmic socket syndrome in a real-world approach. Contact Lens and Anterior Eye. 2024. doi:10.1016/j.clae.2024.102149
BibTeX
@article{Francisco2024,
author = {Francisco, Zamorano-Martín and Sara, Marín-Martínez and José-María, Sánchez-González and Facundo, Urbinati and Carlos, Rocha-de-Lossada and María, García-Lorente and Jessica, Mata and Carmen, Alba-Linero and Santiago, Ortiz-Pérez and Juan Carlos, Sánchez-España},
title = {Standardized clinical evaluation of dry anophthalmic socket syndrome in a real-world approach},
journal = {Contact Lens and Anterior Eye},
year = {2024},
doi = {10.1016/j.clae.2024.102149}
}
EUVIMED