EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Clinical Outcomes of Reintervention After Endoscopic Ultrasound-Guided Hepaticogastrostomy Using a Partially Covered Self-Expandable Metal Stent

Yuhei Iwasa, Akinori Maruta, Keisuke Iwata, Hidetaka Kuroda, Shinya Uemura, Shota Iwata, Yosuke Ohashi, Takuya Koizumi, Kensaku Yoshida, Naoki Mita, Hironao Ichikawa, Takuji Iwashita und 1 weitere

Digestive Diseases and Sciences · 2026-10 · 71 (10) · 4784-4793

DOI: 10.1007/s10620-026-10035-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digestive Diseases and Sciences, online erschienen am 01.06.2026. Verfasst von Yuhei Iwasa und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Gifu Municipal Hospital, Gifu, Japan. Hauptthemen laut MEDLINE: Endosonography, Self Expandable Metallic Stents, Cholestasis, Gastrostomy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Gifu University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Partially covered self-expandable metallic stents (PCSEMSs) used for endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) provide favorable patency and low migration risk; however, reintervention (RI) remains challenging. OBJECTIVES AND METHODS: We retrospectively evaluated the outcomes of RI after EUS-HGS with PCSEMS placement in 108 patients with malignant biliary obstruction treated between January 2016 and December 2024. Causes of recurrent biliary obstruction (RBO), RI techniques, and post-RI outcomes were analyzed. RESULTS: The median age of patients was 77 years, with pancreatic cancer being the most common (n = 62). RBO occurred in 25 (23%) patients, including those with sludge/food impaction (n = 15) and hyperplasia (n = 10). The median time to RBO (TRBO) was 196 days. RI involved PCSEMS removal and replacement (n = 11), or treatment without removal (n = 12). Post-RI RBO developed in six patients (24%), and the median post-RI TRBO was 185 days. The removal group showed a significantly longer TRBO than the nonremoval group (185 vs. 77 days; p = 0.048). Hyperplasia was an independent predictor of failed stent removal (OR, 18.7; 95% CI, 1.45-240; p = 0.02). CONCLUSIONS: Stent removal during RI is associated with longer post-RI TRBO; however, removal can be challenging, particularly in cases with hyperplasia. Careful selection of a PCSEMS for EUS-HGS is required based on the patient's life expectancy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EndosonographySelf Expandable Metallic StentsCholestasisGastrostomyReoperationHumansFemaleAgedRetrospective StudiesMaleAged, 80 and overTreatment OutcomeMiddle AgedDevice Removal

Stichwörter der Autor:innen

Endoscopic ultrasound-guided hepaticogastrostomyMalignant biliary obstructionPartially covered self-expandable metallic stentReintervention

Autor:innen und Institutionen

  • Department of Gastroenterology, Gifu Municipal Hospital, Gifu, Japan.
  • First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan. mrak5844@yahoo.co.jp.
  • First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan.
  • Department of Gastroenterology, Gifu Prefectural General Medical Center, Gifu, Japan.
  • Department of Gastroenterology, Shiga University of Medical Science Hospital, Shiga, Japan.

Förderung

  • Gifu University

Zitieren

APA

Iwasa, Y., Maruta, A., Iwata, K., Kuroda, H., Uemura, S., Iwata, S., Ohashi, Y., Koizumi, T., Yoshida, K., Mita, N., Ichikawa, H., Iwashita, T., & Shimizu, M. (2026). Clinical Outcomes of Reintervention After Endoscopic Ultrasound-Guided Hepaticogastrostomy Using a Partially Covered Self-Expandable Metal Stent. Digestive Diseases and Sciences, 71(10), 4784-4793. https://doi.org/10.1007/s10620-026-10035-3

Vancouver

Iwasa Y, Maruta A, Iwata K, Kuroda H, Uemura S, Iwata S, et al. Clinical Outcomes of Reintervention After Endoscopic Ultrasound-Guided Hepaticogastrostomy Using a Partially Covered Self-Expandable Metal Stent. Digestive Diseases and Sciences. 2026;71(10):4784-4793. doi:10.1007/s10620-026-10035-3

BibTeX
@article{Iwasa2026,
  author = {Iwasa, Yuhei and Maruta, Akinori and Iwata, Keisuke and Kuroda, Hidetaka and Uemura, Shinya and Iwata, Shota and Ohashi, Yosuke and Koizumi, Takuya and Yoshida, Kensaku and Mita, Naoki and Ichikawa, Hironao and Iwashita, Takuji and Shimizu, Masahito},
  title = {Clinical Outcomes of Reintervention After Endoscopic Ultrasound-Guided Hepaticogastrostomy Using a Partially Covered Self-Expandable Metal Stent},
  journal = {Digestive Diseases and Sciences},
  year = {2026},
  volume = {71},
  number = {10},
  pages = {4784--4793},
  doi = {10.1007/s10620-026-10035-3}
}
Kostenlos starten →