Dedicated cautery-enhanced tubular self-expandable metal stent for endoscopic ultrasound-guided hepaticogastrostomy: feasibility study
Endoscopy · 01.11.2024 · 56 (11) · 864-869
DOI: 10.1055/a-2340-7432 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Endoscopy, erschienen am 01.11.2024. Verfasst von Jorge Vargas-Madrigal und 6 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology, Hospital San Juan de Dios, Caja Costarricense de Seguro Social, San Jose, Costa Rica. Hauptthemen laut MEDLINE: Feasibility Studies, Self Expandable Metallic Stents, Endosonography, Cholestasis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 9 Literaturangaben.
Abstract (Originalsprache)
Background
Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is an alternative for biliary drainage in patients with obstructive pancreaticobiliary pathology when endoscopic retrograde cholangiopancreatography (ERCP) is not feasible. Despite its effectiveness, EUS-HGS is associated with a significant risk of adverse events. This study aimed to evaluate the feasibility and safety of a newly designed dedicated cautery-enhanced tubular self-expandable metal stent (SEMS) for EUS-HGS.
Methods
This multicenter prospective study included patients with malignant biliary obstruction in whom ERCP had failed because of tumor infiltration, inability to drain the intrahepatic ducts, or surgically altered anatomy. A dedicated cautery-enhanced tubular SEMS was used for EUS-HGS. Technical and clinical success rates, procedure times, and adverse events were evaluated.
Results
20 patients underwent EUS-HGS with the dedicated stent. Technical and clinical success rates of 100% were achieved, with no reported severe adverse events or mortality. The median procedure time was 16 minutes. Recurrent biliary obstruction was observed in 1 patient.
Conclusions
The dedicated cautery-enhanced tubular SEMS for EUS-HGS can simplify the procedure and enhance its safety and efficacy. This innovation shows promise for improving patient outcomes, although further studies are needed to validate these findings in a broader patient population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Gastroenterology, Hospital San Juan de Dios, Caja Costarricense de Seguro Social, San Jose, Costa Rica.
- Surgery, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong, Hong Kong.
- Gastroenterology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
- Gastroenterology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
- Gastroenterology, Asian Institute of Gastroenterology, Hyderabad, India.
- Gastroenterology, Institut Paoli-Calmettes, Marseille, France.
ORCID-Profile: Jorge Vargas-Madrigal, Shannon M Chan, Anthony Y B Teoh, Jayanta Samanta, Sundeep Lakhtakia
Zitieren
APA
Vargas-Madrigal, J., Chan, S. M., Dhar, J., Teoh, A. Y. B., Samanta, J., Lakhtakia, S., & Giovannini, M. (2024). Dedicated cautery-enhanced tubular self-expandable metal stent for endoscopic ultrasound-guided hepaticogastrostomy: feasibility study. Endoscopy, 56(11), 864-869. https://doi.org/10.1055/a-2340-7432
Vancouver
Vargas-Madrigal J, Chan SM, Dhar J, Teoh AYB, Samanta J, Lakhtakia S, et al. Dedicated cautery-enhanced tubular self-expandable metal stent for endoscopic ultrasound-guided hepaticogastrostomy: feasibility study. Endoscopy. 2024;56(11):864-869. doi:10.1055/a-2340-7432
BibTeX
@article{VargasMadrigal2024,
author = {Vargas-Madrigal, Jorge and Chan, Shannon M and Dhar, Jahnvi and Teoh, Anthony Y B and Samanta, Jayanta and Lakhtakia, Sundeep and Giovannini, Marc},
title = {Dedicated cautery-enhanced tubular self-expandable metal stent for endoscopic ultrasound-guided hepaticogastrostomy: feasibility study},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {11},
pages = {864--869},
doi = {10.1055/a-2340-7432}
}
EUVIMED