Efficacy of endoscopic ultrasound‐guided gastroenterostomy using self‐expandable metallic stent for afferent loop syndrome: A single‐center retrospective study
Journal of Gastroenterology and Hepatology · 2024
DOI: 10.1111/jgh.16649 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Gastroenterology and Hepatology, 2024. Verfasst von Yuya Hagiwara und 24 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Afferent Loop Syndrome, Self Expandable Metallic Stents, Endosonography, Gastroenterostomy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: National Cancer Center Research and Development Fund.
Abstract (Originalsprache)
Background and Aim Endoscopic ultrasound‐guided gastroenterostomy is a procedure used to connect the stomach and dilated afferent loop using a stent under endoscopic ultrasound for afferent loop syndrome. However, the actual efficacy and safety of this procedure remain unclear. Therefore, this retrospective study aimed to evaluate the efficacy and safety of endoscopic ultrasound‐guided gastroenterostomy using a laser‐cut‐type fully covered self‐expandable metallic stent and an anchoring plastic stent for afferent loop syndrome.
Methods
Technical and clinical success rates, adverse events, recurrent intestinal obstruction rates, time to recurrent intestinal obstruction, and technical and clinical success rates of re‐intervention were evaluated in intended patients who underwent endoscopic ultrasound‐guided gastroenterostomy for afferent loop syndrome from October 2018 to August 2022.
Results
In 25 intended patients with afferent loop syndrome who intended endoscopic ultrasound‐guided gastroenterostomy, the technical success rate was 100% (25/25), whereas the clinical success rate was 96% (24/25). Two patients experienced grade ≥ 3 early adverse events, including one with intra‐abdominal abscess and one with hypotension. Both events were attributed to intestinal fluid leakage. No late adverse events were observed. The recurrent intestinal obstruction rate was 32% (8/25), and the median time to recurrent intestinal obstruction was 6.5 months (95% confidence interval: 2.8–not available). The technical and clinical success rates of re‐intervention were both 100% (8/8).
Conclusions
Endoscopic ultrasound‐guided gastroenterostomy using a fully covered self‐expandable metallic stent and an anchoring plastic stent is effective and safe as a treatment procedure for afferent loop syndrome.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan.
- Makati Medical Center, Manila, Philippines.
- Department of Gastroenterology, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
- Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan.
- Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.
ORCID-Profile: Yuya Hagiwara, Susumu Hijioka, Kotaro Takeshita, Daiki Yamashige
Förderung
- National Cancer Center Research and Development Fund
Zitieren
APA
Hagiwara, Y., Hijioka, S., Nagashio, Y., Maruki, Y., Ohba, A., Kawasaki, Y., Takeshita, K., Takasaki, T., Agarie, D., Hara, H., Yagi, S., Fukuda, S., Kuwada, M., Yamashige, D., Okamoto, K., Chatto, M., Kondo, S., Morizane, C., Ueno, H., …, & Okusaka, T. (2024). Efficacy of endoscopic ultrasound‐guided gastroenterostomy using self‐expandable metallic stent for afferent loop syndrome: A single‐center retrospective study. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/jgh.16649
Vancouver
Hagiwara Y, Hijioka S, Nagashio Y, Maruki Y, Ohba A, Kawasaki Y, et al. Efficacy of endoscopic ultrasound‐guided gastroenterostomy using self‐expandable metallic stent for afferent loop syndrome: A single‐center retrospective study. Journal of Gastroenterology and Hepatology. 2024. doi:10.1111/jgh.16649
BibTeX
@article{Hagiwara2024,
author = {Hagiwara, Yuya and Hijioka, Susumu and Nagashio, Yoshikuni and Maruki, Yuta and Ohba, Akihiro and Kawasaki, Yuki and Takeshita, Kotaro and Takasaki, Tetsuro and Agarie, Daiki and Hara, Hidenobu and Yagi, Shin and Fukuda, Soma and Kuwada, Masaru and Yamashige, Daiki and Okamoto, Kohei and Chatto, Mark and Kondo, Shunsuke and Morizane, Chigusa and Ueno, Hideki and Endo, Masato and Sugawara, Shunsuke and Sone, Miyuki and Saito, Yutaka and Tsuchiya, Kiichiro and Okusaka, Takuji},
title = {Efficacy of endoscopic ultrasound‐guided gastroenterostomy using self‐expandable metallic stent for afferent loop syndrome: A single‐center retrospective study},
journal = {Journal of Gastroenterology and Hepatology},
year = {2024},
doi = {10.1111/jgh.16649}
}
EUVIMED