Agreement and reproducibility between 3DStent vs. Optical Coherence Tomography for evaluation of stent area and diameter
The International Journal of Cardiovascular Imaging · 2024
DOI: 10.1007/s10554-024-03268-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Andrea Ruberti und 6 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Clinic Institute, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Hospital Clínic, University of Barcelona, c/ Vil…. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Predictive Value of Tests, Coronary Vessels, Percutaneous Coronary Intervention. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitat de Barcelona.
Abstract (Originalsprache)
3DStent is a novel rotational angiography imaging capable of 3D reconstruction and measuring stent area and diameter, without need for intravascular imaging. To compare 3DStent and OCT-derived stent area and diameter after PCI. Patients with de novo coronary lesions who underwent treatment with a single DES and evaluated by OCT and 3DStent were included. Stent area and diameter were measured by 3DStent, at abluminal, mid and endoluminal side and by OCT. From September 2023 to February 2024 six coronary lesions were analyzed. Post-PCI stent area measured by OCT was (mean ± standard deviation) 7.03 ± 2.85 mm 2 and by 3DStent 9.41 ± 2.79 mm 2 , 7.21 ± 2.23 mm 2 and 5.63 ± 1.83 mm 2 at abluminal, mid and endoluminal side, respectively. Stent diameter by OCT was 2.93 ± 0.58 mm, and by 3DStent 3.27 ± 0.50 mm, 2.86 ± 0.49 mm and 2.52 ± 0.45 mm at abluminal, mid and endoluminal side, respectively. Significant correlation was observed between OCT and 3DStent in relation to stent area (Exp(B) 3.35, mean of difference 0.19 ± 1.01 mm 2 , 95%CI -1.80–2.17 mm 2 , p < 0.001) and diameter (Exp(B) 3.18, mean difference − 0.07 ± 0.18 mm, 95%CI -0.43–0.30 mm, p < 0.001), particularly when 3DStent measurements performed at the mid side. Very high reproducibility was demonstrated by intra- and inter-observer analysis ( r = 0.92 and r = 0.93 respectively). 3DStent appears to be an easy and reproducible tool to assess post-PCI stent area and diameter as compared to OCT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiovascular Clinic Institute, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Hospital Clínic, University of Barcelona, c/ Villarroel 170, Barcelona, 08036, Spain.
- GE HealthCare, Buc, France.
- Galeazzi-Sant'Ambrogio Hospital IRCCS, Milan, Italy.
- Cardiovascular Clinic Institute, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Hospital Clínic, University of Barcelona, c/ Villarroel 170, Barcelona, 08036, Spain. sabrugaletta@gmail.com.
- Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona (UB), 08036, Barcelona, Spain. sabrugaletta@gmail.com.
Förderung
- Universitat de Barcelona
Zitieren
APA
Ruberti, A., Rinaldi, R., Occhipinti, G., Ramus, L., Guagliumi, G., Sabate, M., & Brugaletta, S. (2024). Agreement and reproducibility between 3DStent vs. Optical Coherence Tomography for evaluation of stent area and diameter. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03268-8
Vancouver
Ruberti A, Rinaldi R, Occhipinti G, Ramus L, Guagliumi G, Sabate M, et al. Agreement and reproducibility between 3DStent vs. Optical Coherence Tomography for evaluation of stent area and diameter. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03268-8
BibTeX
@article{Ruberti2024,
author = {Ruberti, Andrea and Rinaldi, Riccardo and Occhipinti, Giovanni and Ramus, Liliane and Guagliumi, Giulio and Sabate, Manel and Brugaletta, Salvatore},
title = {Agreement and reproducibility between 3DStent vs. Optical Coherence Tomography for evaluation of stent area and diameter},
journal = {The International Journal of Cardiovascular Imaging},
year = {2024},
doi = {10.1007/s10554-024-03268-8}
}
EUVIMED