EUVIMEDEUVIMED entdecken
Open Access

Diagnostic accuracy of a novel optical coherence tomography-based fractional flow reserve algorithm for assessment of coronary stenosis significance

Weili Pan, Wenjuan Wei, Yumeng Hu iD, Li Feng, Yongkui Ren, Xinsheng Li, Changling Li, Jun Jiang, Jianping Xiang, Xiaochang Leng, Da Yin

Cardiology Journal · 2024

DOI: 10.5603/cj.90744 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiology Journal, 2024. Verfasst von Weili Pan und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Tomography, Optical Coherence, Coronary Stenosis, Coronary Angiography. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study aimed to introduce a novel optical coherence tomography-derived fractional flow reserve (FFR) computational approach and assess the diagnostic performance of the algorithm for assessing physiological function. METHODS: The fusion of coronary optical coherence tomography and angiography was used to generate a novel FFR algorithm (AccuFFRoct) to evaluate functional ischemia of coronary stenosis. In the current study, a total of 34 consecutive patients were included, and AccuFFRoct was used to calculate the FFR for these patients. With the wire-measured FFR as the reference standard, we evaluated the performance of our approach by accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: Per vessel accuracy, sensitivity, specificity, PPV, and NPV for AccuFFRoct in identifying hemodynamically significant coronary stenosis were 93.8%, 94.7%, 92.3%, 94.7%, and 92.3%, respectively, were found. Good correlation (Pearson's correlation coefficient r = 0.80, p < 0.001) between AccuFFRoct and FFR was observed. The Bland-Altman analysis showed a mean difference value of -0.037 (limits of agreement: -0.189 to 0.115). The area under the receiver-operating characteristic curve (AUC) of AccuFFRoct in identifying physiologically significant stenosis was 0.94, which was higher than the minimum lumen area (MLA, AUC = 0.91) and significantly higher than the diameter stenosis (%DS, AUC = 0.78). CONCLUSIONS: This clinical study shows the efficiency and accuracy of AccuFFRoct for clinical implementation when using invasive FFR measurement as a reference. It could provide important insights into coronary imaging superior to current methods based on the degree of coronary artery stenosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialTomography, Optical CoherenceCoronary StenosisCoronary AngiographyAlgorithmsCoronary VesselsPredictive Value of TestsSeverity of Illness IndexHumansFemaleMaleMiddle AgedReproducibility of ResultsAgedROC CurveCardiac Catheterization

Stichwörter der Autor:innen

angiographycoronary stenosisfractional flow reserveoptical coherence tomographythree-dimensional reconstruction

Autor:innen und Institutionen

  • Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
  • Department of Cardiology, The First People's Hospital of Xiaoshan District, Hangzhou, China.
  • ArteryFlow Technology Co., Ltd., Hangzhou, China. yumeng.hu@arteryflow.com.
  • ArteryFlow Technology Co., Ltd., Hangzhou, China.
  • Department of Cardiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Department of Cardiology, Shenzhen Cardiovascular Minimally Invasive Medical Engineering Technology Research and Development Center, Shenzhen People's Hospital, Shenzhen, China.

ORCID-Profile: Yumeng Hu

Zitieren

APA

Pan, W., Wei, W., Hu, Y., Feng, L., Ren, Y., Li, X., Li, C., Jiang, J., Xiang, J., Leng, X., & Yin, D. (2024). Diagnostic accuracy of a novel optical coherence tomography-based fractional flow reserve algorithm for assessment of coronary stenosis significance. Cardiology Journal. https://doi.org/10.5603/cj.90744

Vancouver

Pan W, Wei W, Hu Y, Feng L, Ren Y, Li X, et al. Diagnostic accuracy of a novel optical coherence tomography-based fractional flow reserve algorithm for assessment of coronary stenosis significance. Cardiology Journal. 2024. doi:10.5603/cj.90744

BibTeX
@article{Pan2024,
  author = {Pan, Weili and Wei, Wenjuan and Hu, Yumeng and Feng, Li and Ren, Yongkui and Li, Xinsheng and Li, Changling and Jiang, Jun and Xiang, Jianping and Leng, Xiaochang and Yin, Da},
  title = {Diagnostic accuracy of a novel optical coherence tomography-based fractional flow reserve algorithm for assessment of coronary stenosis significance},
  journal = {Cardiology Journal},
  year = {2024},
  doi = {10.5603/cj.90744}
}
Kostenlos starten →