Comparison of Artificial Intelligence Automated Quantification and Visual Assessment in Optical Coherence Tomography Images (CONTEST)
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70157 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Naotaka Okamoto und 13 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Osaka Rosai Hospital, Osaka, Japan. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Coronary Artery Disease, Percutaneous Coronary Intervention, Artificial Intelligence. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Background
Optical coherence tomography (OCT) with artificial intelligence (AI) has been developed.
Aims
The study aimed to evaluate the differences between AI‐quantified and visual assessments.
Methods
Patients scheduled for OCT‐guided percutaneous coronary intervention between September 2021 and October 2022 were included. AI‐quantified OCT pullback and another visually assessed pullback were acquired. The two pullbacks were manually analyzed offline after the procedure (visual analysis 1 and 2). The calcium parameters and vessel size quantified by AI in the corresponding cross‐sections assessed in visual analysis 1 were selected (AI‐quantified analysis). Intraclass correlation coefficients (ICC) were computed, and Bland−Altman analysis was performed. Subsequent procedural strategies based on the AI‐quantified and visual assessments were compared.
Results
The concordance of calcified plaque presence between AI‐quantified analysis and visual analysis 1 or 2 was 83%. The ICC of calcium length between AI‐quantified analysis and visual analysis 1 or 2 was above 0.80. However, the ICC values were below 0.75 in maximum calcium angle, the mean calcium angle, and the maximum calcium thickness. The Bland−Altman plots indicated that the calcium angle and thickness quantified by AI were greater than those assessed visually. The ICC for EEL and lumen diameters at proximal and distal references were all approximately above 0.90. There was no difference between the strategies based on the AI‐quantified and visual assessments.
Conclusions
AI‐quantified assessments tended to overestimate calcium presence and parameters compared to visual assessments. However, vessel sizes demonstrated excellent correspondence. Strategies were similarly developed based on both assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Osaka Rosai Hospital, Osaka, Japan.
ORCID-Profile: Naotaka Okamoto, Yasuyuki Egami, Yasuharu Matsunaga-Lee, Masami Nishino
Zitieren
APA
Okamoto, N., Egami, Y., Fujii, S., Mikako, K., Mukai, T., Sugino, A., Kobayashi, N., Abe, M., Nohara, H., Kawanami, S., Yasumoto, K., Matsunaga-Lee, Y., Yano, M., & Nishino, M. (2025). Comparison of Artificial Intelligence Automated Quantification and Visual Assessment in Optical Coherence Tomography Images (CONTEST). Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70157
Vancouver
Okamoto N, Egami Y, Fujii S, Mikako K, Mukai T, Sugino A, et al. Comparison of Artificial Intelligence Automated Quantification and Visual Assessment in Optical Coherence Tomography Images (CONTEST). Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70157
BibTeX
@article{Okamoto2025,
author = {Okamoto, Naotaka and Egami, Yasuyuki and Fujii, Subaru and Mikako, Kise and Mukai, Taichi and Sugino, Ayako and Kobayashi, Noriyuki and Abe, Masaru and Nohara, Hiroaki and Kawanami, Shodai and Yasumoto, Koji and Matsunaga-Lee, Yasuharu and Yano, Masamichi and Nishino, Masami},
title = {Comparison of Artificial Intelligence Automated Quantification and Visual Assessment in Optical Coherence Tomography Images (CONTEST)},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70157}
}
EUVIMED