EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated adaptive detection and reconstruction of quiescent cardiac phases in free-running whole-heart acquisitions using Synchronicity Maps from PHysiological mOtioN In Cine (SYMPHONIC) MRI

Giulia M C Rossi Bongiolatti, Nemanja Masala, Jessica A M Bastiaansen, Jérôme Yerly, Milan Prša, Tobias Rutz, Estelle Tenisch, Salim Si-Mohamed, Matthias Stuber, Christopher W Roy

Magnetic Resonance Materials in Physics, Biology and Medicine · 2025

DOI: 10.1007/s10334-025-01289-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von Giulia M C Rossi Bongiolatti und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Rue de Bugnon 46, BH-7-84, 1011, Lausanne, Switzerlan…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cine, Heart, Image Processing, Computer-Assisted. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, University of Lausanne.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To reconstruct whole-heart images from free-running acquisitions through automated selection of data acceptance windows (ES: end-systole, MD: mid-diastole, ED: end-diastole) that account for heart rate variability (HRV).

Methods

SYMPHONIC was developed and validated in simulated ( N = 1000) and volunteer ( N = 14) data. To validate SYMPHONIC, the position of the detected acceptance windows, total duration, and resulting ventricular volume were compared to the simulated ground truth to establish metrics for temporal error, quiescent interval duration, and volumetric error, respectively. SYMPHONIC MD images and those using manually defined acceptance windows with fixed (MANUAL FIXED ) or adaptive (MANUAL ADAPT ) width were compared by measuring vessel sharpness (VS). The impact of HRV was assessed in patients ( N = 6).

Results

Mean temporal error was larger for MD than for ED and ED in both simulations and volunteers. Mean volumetric errors were comparable. Interval duration differed for ES ( p = 0.04) and ED ( p < 10 –3 ), but not for MD ( p = 0.08). In simulations, SYMPHONIC and MANUAL ADAPT provided consistent VS for increasing HRV, while VS decreased for MANUAL FIXED . In volunteers, VS differed between MANUAL ADAPT and MANUAL FIXED ( p < 0.01), but not between SYMPHONIC and MANUAL ADAPT ( p = 0.03) or MANUAL FIXED ( p = 0.42).

Conclusion

SYMPHONIC accurately detected quiescent cardiac phases in free-running data and resulted in high-quality whole-heart images despite the presence of HRV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance Imaging, CineHeartImage Processing, Computer-AssistedHumansHeart RateMaleAlgorithmsAdultFemaleReproducibility of ResultsComputer SimulationMotionMiddle AgedSystoleImage Interpretation, Computer-AssistedDiastole

Stichwörter der Autor:innen

Automated detectionFree-runningHeart rate variabilityQuiescent cardiac phasesWhole-heart

Autor:innen und Institutionen

  • Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Rue de Bugnon 46, BH-7-84, 1011, Lausanne, Switzerland.
  • Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, InselspitalLausanne, Switzerland.
  • Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland.
  • Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.
  • Division of Pediatric Cardiology, Woman-Mother-Child Department, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
  • Service of Cardiology, Heart and Vessel Department, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.

Förderung

  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
  • University of Lausanne

Zitieren

APA

Bongiolatti, G. M. C. R., Masala, N., Bastiaansen, J. A. M., Yerly, J., Prša, M., Rutz, T., Tenisch, E., Si-Mohamed, S., Stuber, M., & Roy, C. W. (2025). Automated adaptive detection and reconstruction of quiescent cardiac phases in free-running whole-heart acquisitions using Synchronicity Maps from PHysiological mOtioN In Cine (SYMPHONIC) MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01289-5

Vancouver

Bongiolatti GMCR, Masala N, Bastiaansen JAM, Yerly J, Prša M, Rutz T, et al. Automated adaptive detection and reconstruction of quiescent cardiac phases in free-running whole-heart acquisitions using Synchronicity Maps from PHysiological mOtioN In Cine (SYMPHONIC) MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01289-5

BibTeX
@article{Bongiolatti2025,
  author = {Bongiolatti, Giulia M C Rossi and Masala, Nemanja and Bastiaansen, Jessica A M and Yerly, Jérôme and Prša, Milan and Rutz, Tobias and Tenisch, Estelle and Si-Mohamed, Salim and Stuber, Matthias and Roy, Christopher W},
  title = {Automated adaptive detection and reconstruction of quiescent cardiac phases in free-running whole-heart acquisitions using Synchronicity Maps from PHysiological mOtioN In Cine (SYMPHONIC) MRI},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2025},
  doi = {10.1007/s10334-025-01289-5}
}
Kostenlos starten →