EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Single‐Frequency Birdcage Coils for Deep Tissue Perfluorocarbon Magnetic Resonance Imaging in Mice

Sean W McRae, Francisco M Martinez, Paula J Foster, John A Ronald, Timothy J Scholl iD

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.5296 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Sean W McRae und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada. Hauptthemen laut MEDLINE: Fluorocarbons, Phantoms, Imaging, Signal-To-Noise Ratio. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fluorine‐19 ( 19 F) MRI has become an established tool for in vivo cell tracking following ex vivo or in vivo labelling of various cell types with 19 F perfluorocarbons (PFCs). Here, we developed and evaluated novel mouse‐specific radiofrequency (RF) hardware for improved dual 1 H anatomical imaging and deep tissue 19 F MR detection of PFCs. Three linearly polarized birdcage RF coils were constructed—a dual‐frequency 1 H/ 19 F coil, and a pair of single‐frequency 1 H and 19 F coils, designed to be used sequentially. RF coil quality factors ( Q values ), signal homogeneity and sensitivity were benchmarked against a commercially constructed dual‐frequency 1 H/ 19 F surface coil. RF homogeneity was assessed using a phantom designed to mimic PFC localization at depth in a mouse. The single‐frequency birdcage coils ( 1 H and 19 F) displayed more uniform coverage and enhanced signal‐to‐noise ratios (SNRs) compared to both the birdcage and surface dual‐frequency coils for 19 F detection. Bilateral injection of a perfluoropolyether nanoemulsion into the footpads of female athymic nude mice, resulting in drainage to various lymph nodes and subsequent accumulation in lymph node macrophages, provided a platform to assess differences in SNRs and contrast‐to‐noise ratios (CNR) between both coil configurations as a function of depth and location. The single‐frequency 1 H coil provided significantly increased CNR in anatomical images ( p < 0.001) with increased anatomical coverage compared to the dual‐frequency surface coil. The single‐frequency 19 F birdcage coil offered increased PFC detectability with significantly higher SNR in renal, lumbar, sciatic and popliteal lymph nodes ( p < 0.01) compared to the dual‐frequency surface coil. Interestingly, the percentage difference between SNR measurements in lymph nodes between the single‐frequency 19 F coil and the 1 H/ 19 F surface coil had a linear relationship with increasing distance from the surface coil ( R 2 = 0.6352; p < 0.0001), indicating a potential disagreement for imaging experiments that rely on 19 F spin quantification at increasing depth within the mouse using surface RF coils.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FluorocarbonsPhantoms, ImagingSignal-To-Noise RatioAnimalsMiceMagnetic Resonance ImagingFluorine-19 Magnetic Resonance ImagingFemaleMice, NudeRadio Waves

Stichwörter der Autor:innen

19F and 1H radiofrequency hardware developmentcell trackingperfluorocarbon imagingsmall animal imaging

Substanzen

Fluorocarbons

Autor:innen und Institutionen

  • Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada.
  • Imaging Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario, Canada.
  • Lawson Health Research Institute, St. Joseph's Health Care, London, Ontario, Canada.
  • Department of Physics and Astronomy, University of Western Ontario, London, Ontario, Canada.
  • Ontario Institute for Cancer Research, Toronto, Ontario, Canada.

ORCID-Profile: Timothy J Scholl

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

McRae, S. W., Martinez, F. M., Foster, P. J., Ronald, J. A., & Scholl, T. J. (2025). Single‐Frequency Birdcage Coils for Deep Tissue Perfluorocarbon Magnetic Resonance Imaging in Mice. NMR in Biomedicine. https://doi.org/10.1002/nbm.5296

Vancouver

McRae SW, Martinez FM, Foster PJ, Ronald JA, Scholl TJ. Single‐Frequency Birdcage Coils for Deep Tissue Perfluorocarbon Magnetic Resonance Imaging in Mice. NMR in Biomedicine. 2025. doi:10.1002/nbm.5296

BibTeX
@article{McRae2025,
  author = {McRae, Sean W and Martinez, Francisco M and Foster, Paula J and Ronald, John A and Scholl, Timothy J},
  title = {Single‐Frequency Birdcage Coils for Deep Tissue Perfluorocarbon Magnetic Resonance Imaging in Mice},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.5296}
}
Kostenlos starten →