EUVIMEDEUVIMED entdecken
Crossref

Impact of super-resolution deep learning-based reconstruction for hippocampal MRI: A volunteer and phantom study

Sentaro Takada, Takeshi Nakaura, Naofumi Yoshida, Hiroyuki Uetani, Kaori Shiraishi, Naoki Kobayashi, Kensei Matsuo, Kosuke Morita, Yasunori Nagayama, Masafumi Kidoh, Yuichi Yamashita, Ryohei Takayanagi und 1 weitere

European Journal of Radiology · 2025

DOI: 10.1016/j.ejrad.2025.112289 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology, 2025. Verfasst von Sentaro Takada und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto 860-8556, Japan. Electronic addre…. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Hippocampus, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Kumamoto University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: To evaluate the effects of super-resolution deep learning-based reconstruction (SR-DLR) on thin-slice T2-weighted hippocampal MR image quality using 3 T MRI, in both human volunteers and phantoms. MATERIALS AND METHODS: Thirteen healthy volunteers underwent hippocampal MRI at standard and high resolutions. Original (standard-resolution; StR) images were reconstructed with and without deep learning-based reconstruction (DLR) (Matrix = 320 × 320), and with SR-DLR (Matrix = 960 × 960). High-resolution (HR) images were also reconstructed with/without DLR (Matrix = 960 × 960). Contrast, contrast-to-noise ratio (CNR), and septum slope were analyzed. Two radiologists evaluated the images for noise, contrast, artifacts, sharpness, and overall quality. Quantitative and qualitative results are reported as medians and interquartile ranges (IQR). Comparisons used the Wilcoxon signed-rank test with Holm correction. We also scanned an American College of Radiology (ACR) phantom to evaluate the ability of our SR-DLR approach to reduce artifacts induced by zero-padding interpolation (ZIP). RESULTS: SR-DLR exhibited contrast comparable to original images and significantly higher than HR-images. Its slope was comparable to that of HR images but was significantly steeper than that of StR images (p < 0.01). Furthermore, the CNR of SR-DLR (10.53; IQR: 10.08, 11.69) was significantly superior to the StR-images without DLR (7.5; IQR: 6.4, 8.37), StR-images with DLR (8.73; IQR: 7.68, 9.0), HR-images without DLR (2.24; IQR: 1.43, 2.38), and HR-images with DLR (4.84; IQR: 2.99, 5.43) (p < 0.05). In the phantom study, artifacts induced by ZIP were scarcely observed when using SR-DLR. CONCLUSION: SR-DLR for hippocampal MRI potentially improves image quality beyond that of actual HR-images while reducing acquisition time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningMagnetic Resonance ImagingHippocampusImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedHumansPhantoms, ImagingMaleAdultFemaleHealthy VolunteersArtifactsSignal-To-Noise Ratio

Stichwörter der Autor:innen

Deep learningHippocampusImage reconstructionMagnetic resonance imagingSuper-resolution

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto 860-8556, Japan. Electronic address: takada.s.0211@outlook.jp.
  • Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto 860-8556, Japan. Electronic address: kff00712@nifty.com.
  • Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto 860-8556, Japan. Electronic address: naofumi.yoshida.hf@riken.jp.
  • Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto 860-8556, Japan. Electronic address: uh948@kuh.kumamoto-u.ac.jp.
  • Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto 860-8556, Japan. Electronic address: kaorinpa27@gmail.com.
  • Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto 860-8556, Japan. Electronic address: 216r5124@st.kumamoto-u.ac.jp.

Förderung

  • Kumamoto University

Zitieren

APA

Takada, S., Nakaura, T., Yoshida, N., Uetani, H., Shiraishi, K., Kobayashi, N., Matsuo, K., Morita, K., Nagayama, Y., Kidoh, M., Yamashita, Y., Takayanagi, R., & Hirai, T. (2025). Impact of super-resolution deep learning-based reconstruction for hippocampal MRI: A volunteer and phantom study. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112289

Vancouver

Takada S, Nakaura T, Yoshida N, Uetani H, Shiraishi K, Kobayashi N, et al. Impact of super-resolution deep learning-based reconstruction for hippocampal MRI: A volunteer and phantom study. European Journal of Radiology. 2025. doi:10.1016/j.ejrad.2025.112289

BibTeX
@article{Takada2025,
  author = {Takada, Sentaro and Nakaura, Takeshi and Yoshida, Naofumi and Uetani, Hiroyuki and Shiraishi, Kaori and Kobayashi, Naoki and Matsuo, Kensei and Morita, Kosuke and Nagayama, Yasunori and Kidoh, Masafumi and Yamashita, Yuichi and Takayanagi, Ryohei and Hirai, Toshinori},
  title = {Impact of super-resolution deep learning-based reconstruction for hippocampal MRI: A volunteer and phantom study},
  journal = {European Journal of Radiology},
  year = {2025},
  doi = {10.1016/j.ejrad.2025.112289}
}
Kostenlos starten →