EUVIMEDEUVIMED entdecken
Open Access

High-resolution prostate diffusion MRI using eddy current-nulled convex optimized diffusion encoding and random matrix theory-based denoising

Zhaohuan Zhang, Elif Aygun, Shu-Fu Shih, Steven S Raman, Kyunghyun Sung, Holden H Wu

Magnetic Resonance Materials in Physics, Biology and Medicine · 2024

DOI: 10.1007/s10334-024-01147-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2024. Verfasst von Zhaohuan Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Signal-To-Noise Ratio, Prostatic Neoplasms, Prostate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Institutes of Health (NIH), UCLA Radiological Sciences and Pathology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To develop and evaluate a technique combining eddy current-nulled convex optimized diffusion encoding (ENCODE) with random matrix theory (RMT)-based denoising to accelerate and improve the apparent signal-to-noise ratio (aSNR) and apparent diffusion coefficient (ADC) mapping in high-resolution prostate diffusion-weighted MRI (DWI). MATERIALS AND METHODS: Eleven subjects with clinical suspicion of prostate cancer were scanned at 3T with high-resolution (HR) (in-plane: 1.0 × 1.0 mm2) ENCODE and standard-resolution (1.6 × 2.2 mm2) bipolar DWI sequences (both had 7 repetitions for averaging, acquisition time [TA] of 5 min 50 s). HR-ENCODE was retrospectively analyzed using three repetitions (accelerated effective TA of 2 min 30 s). The RMT-based denoising pipeline utilized complex DWI signals and Marchenko-Pastur distribution-based principal component analysis to remove additive Gaussian noise in images from multiple coils, b-values, diffusion encoding directions, and repetitions. HR-ENCODE with RMT-based denoising (HR-ENCODE-RMT) was compared with HR-ENCODE in terms of aSNR in prostate peripheral zone (PZ) and transition zone (TZ). Precision and accuracy of ADC were evaluated by the coefficient of variation (CoV) between repeated measurements and mean difference (MD) compared to the bipolar ADC reference, respectively. Differences were compared using two-sided Wilcoxon signed-rank tests (P < 0.05 considered significant). RESULTS: HR-ENCODE-RMT yielded 62% and 56% higher median aSNR than HR-ENCODE (b = 800 s/mm2) in PZ and TZ, respectively (P < 0.001). HR-ENCODE-RMT achieved 63% and 70% lower ADC-CoV than HR-ENCODE in PZ and TZ, respectively (P < 0.001). HR-ENCODE-RMT ADC and bipolar ADC had low MD of 22.7 × 10-6 mm2/s in PZ and low MD of 90.5 × 10-6 mm2/s in TZ. CONCLUSIONS: HR-ENCODE-RMT can shorten the acquisition time and improve the aSNR of high-resolution prostate DWI and achieve accurate and precise ADC measurements in the prostate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingSignal-To-Noise RatioProstatic NeoplasmsProstateAlgorithmsImage Processing, Computer-AssistedHumansMaleMiddle AgedRetrospective StudiesAgedImage Interpretation, Computer-AssistedPrincipal Component AnalysisImage EnhancementArtifactsReproducibility of Results

Stichwörter der Autor:innen

DenoisingDiffusion MRIHigh-resolution diffusion MRIProstateRandom matrix theory

Autor:innen und Institutionen

  • Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA.
  • Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
  • Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA. HoldenWu@mednet.ucla.edu.
  • Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA. HoldenWu@mednet.ucla.edu.

Förderung

  • NCI NIH HHS
  • National Institutes of Health (NIH)
  • UCLA Radiological Sciences and Pathology
  • Jonsson Comprehensive Cancer Center

Zitieren

APA

Zhang, Z., Aygun, E., Shih, S. F., Raman, S. S., Sung, K., & Wu, H. H. (2024). High-resolution prostate diffusion MRI using eddy current-nulled convex optimized diffusion encoding and random matrix theory-based denoising. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-024-01147-w

Vancouver

Zhang Z, Aygun E, Shih SF, Raman SS, Sung K, Wu HH. High-resolution prostate diffusion MRI using eddy current-nulled convex optimized diffusion encoding and random matrix theory-based denoising. Magnetic Resonance Materials in Physics, Biology and Medicine. 2024. doi:10.1007/s10334-024-01147-w

BibTeX
@article{Zhang2024,
  author = {Zhang, Zhaohuan and Aygun, Elif and Shih, Shu-Fu and Raman, Steven S and Sung, Kyunghyun and Wu, Holden H},
  title = {High-resolution prostate diffusion MRI using eddy current-nulled convex optimized diffusion encoding and random matrix theory-based denoising},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2024},
  doi = {10.1007/s10334-024-01147-w}
}
Kostenlos starten →