EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Image distortion correction for MRI in low field permanent magnet systems with strong B0 inhomogeneity and gradient field nonlinearities

Kirsten Koolstra, Thomas O'Reilly, Peter Börnert, Andrew Webb

Magnetic Resonance Materials in Physics, Biology and Medicine · 2021-08 · 34 (4) · 631-642

DOI: 10.1007/s10334-021-00907-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 27.01.2021. Verfasst von Kirsten Koolstra und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology, Division of Image Processing, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands. K.Koolstra@lumc.nl. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Magnets. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Advanced Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To correct for image distortions produced by standard Fourier reconstruction techniques on low field permanent magnet MRI systems with strong $${B}_{0}$$ B 0 inhomogeneity and gradient field nonlinearities. Materials and methods Conventional image distortion correction algorithms require accurate $${\Delta B}_{0}$$ Δ B 0 maps which are not possible to acquire directly when the $${B}_{0}$$ B 0 inhomogeneities also produce significant image distortions. Here we use a readout gradient time-shift in a TSE sequence to encode the $${B}_{0}$$ B 0 field inhomogeneities in the k-space signals. Using a non-shifted and a shifted acquisition as input, $$\Delta {B}_{0}$$ Δ B 0 maps and images were reconstructed in an iterative manner. In each iteration, $$\Delta {B}_{0}$$ Δ B 0 maps were reconstructed from the phase difference using Tikhonov regularization, while images were reconstructed using either conjugate phase reconstruction (CPR) or model-based (MB) image reconstruction, taking the reconstructed field map into account. MB reconstructions were, furthermore, combined with compressed sensing (CS) to show the flexibility of this approach towards undersampling. These methods were compared to the standard fast Fourier transform (FFT) image reconstruction approach in simulations and measurements. Distortions due to gradient nonlinearities were corrected in CPR and MB using simulated gradient maps.

Results

Simulation results show that for moderate field inhomogeneities and gradient nonlinearities, $$\Delta {B}_{0}$$ Δ B 0 maps and images reconstructed using iterative CPR result in comparable quality to that for iterative MB reconstructions. However, for stronger inhomogeneities, iterative MB reconstruction outperforms iterative CPR in terms of signal intensity correction. Combining MB with CS, similar image and $$\Delta {B}_{0}$$ Δ B 0 map quality can be obtained without a scan time penalty. These findings were confirmed by experimental results.

Discussion

In case of $${B}_{0}$$ B 0 inhomogeneities in the order of kHz, iterative MB reconstructions can help to improve both image quality and $$\Delta {B}_{0}$$ Δ B 0 map estimation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingMagnetsAlgorithmsComputer SimulationFourier AnalysisImage Processing, Computer-AssistedPhantoms, Imaging

Stichwörter der Autor:innen

B0 mappingConjugate phase reconstructionDistortion correctionLow field MRIModel-based reconstruction

Autor:innen und Institutionen

  • Radiology, Division of Image Processing, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands. K.Koolstra@lumc.nl.
  • Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
  • Philips Research, Röntgenstraβe 24-26, 22335, Hamburg, Germany.

Förderung

  • European Research Advanced Grant

Zitieren

APA

Koolstra, K., O'Reilly, T., Börnert, P., & Webb, A. (2021). Image distortion correction for MRI in low field permanent magnet systems with strong B0 inhomogeneity and gradient field nonlinearities. Magnetic Resonance Materials in Physics, Biology and Medicine, 34(4), 631-642. https://doi.org/10.1007/s10334-021-00907-2

Vancouver

Koolstra K, O'Reilly T, Börnert P, Webb A. Image distortion correction for MRI in low field permanent magnet systems with strong B0 inhomogeneity and gradient field nonlinearities. Magnetic Resonance Materials in Physics, Biology and Medicine. 2021;34(4):631-642. doi:10.1007/s10334-021-00907-2

BibTeX
@article{Koolstra2021,
  author = {Koolstra, Kirsten and O'Reilly, Thomas and Börnert, Peter and Webb, Andrew},
  title = {Image distortion correction for MRI in low field permanent magnet systems with strong B0 inhomogeneity and gradient field nonlinearities},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2021},
  volume = {34},
  number = {4},
  pages = {631--642},
  doi = {10.1007/s10334-021-00907-2}
}
Kostenlos starten →