EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses

Luis Hernandez-Garcia iD, Alberto L Vazquez, Douglas C Noll iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.70218 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Luis Hernandez-Garcia und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, NIBIB NIH HHS, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The goal of this article is to introduce a technique to measure the velocity distribution of water inside each voxel of an MR image. The method is based on the use of motion sensitizing gradients with changing first moment to encode velocity. As such, it is completely non‐invasive and requires no contrast injections.

Methods

The technique consists of acquiring a series of images preceded by preparatory RF pulses that encode velocity information, analogously to k‐space encoding. The velocity distribution can be decoded via the Fourier transform. We demonstrate its use on a simple flow phantom with known flow characteristics. We demonstrate the technique on the brains of five human participants from whom we collected the velocity distribution along each of the three laboratory axes.

Results

Velocity distribution measurements on simple phantoms yielded velocity distributions consistent with theory. Human velocity spectra identified specific anatomical features at different velocity bins. The largest fraction of spins was in the lowest velocity bands. Movement in the CSF spaces could be clearly identified at different velocity bands.

Conclusion

Velocity Spectrum Imaging has great potential as a tool to study the movement of fluids in the human body without contrast agents. In addition to a useful tool for validating computational fluid dynamic models in vivo, it can be used to study the complex movement of water in the glymphatic system and its involvement in neurodegenerative disorders. However, further development is needed to probe the velocity spectrum in the ultra‐low velocity regime of the perivascular spaces.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainHumansPhantoms, ImagingAlgorithmsImage Processing, Computer-AssistedFourier AnalysisAdultMale

Autor:innen und Institutionen

  • Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
  • Center for Neuroscience, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

ORCID-Profile: Luis Hernandez-Garcia, Douglas C Noll

Förderung

  • NINDS NIH HHS
  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Hernandez-Garcia, L., Vazquez, A. L., & Noll, D. C. (2025). Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70218

Vancouver

Hernandez-Garcia L, Vazquez AL, Noll DC. Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70218

BibTeX
@article{HernandezGarcia2025,
  author = {Hernandez-Garcia, Luis and Vazquez, Alberto L and Noll, Douglas C},
  title = {Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.70218}
}
Kostenlos starten →