EUVIMEDEUVIMED entdecken
Open Access · CC BY 2.0

Sodium (23Na) ultra-short echo time imaging in the human brain using a 3D-Cones trajectory

Frank Riemer, Bhavana S Solanky, Christian Stehning, Matthew Clemence, Claudia A M Wheeler-Kingshott, Xavier Golay

Magnetic Resonance Materials in Physics, Biology and Medicine · 2014-02 · 27 (1) · 35-46

DOI: 10.1007/s10334-013-0395-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 31.07.2013. Verfasst von Frank Riemer und 5 weiteren Autor:innen. Beteiligte Einrichtung: NMR Research Unit, Department of Neuroinflammation, Queen Square MS Centre, UCL Institute of Neurology, Queen Square, London, WC1N 3BG, UK, frank.rie…. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 2.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECT: Sodium magnetic resonance imaging ((23)Na-MRI) of the brain has shown changes in (23)Na signal as a hallmark of various neurological diseases such as stroke, Alzheimer's disease, Multiple Sclerosis and Huntington's disease. To improve scan times and image quality, we have implemented the 3D-Cones (CN) sequence for in vivo (23)Na brain MRI. MATERIALS AND METHODS: Using signal-to-noise (SNR) as a measurement of sequence performance, CN is compared against more established 3D-radial k-space sampling schemes featuring cylindrical stack-of-stars (SOS) and 3D-spokes kooshball (KB) trajectories, on five healthy volunteers in a clinical setting. Resolution was evaluated by simulating the point-spread-functions (PSFs) and experimental measures on a phantom. RESULTS: All sequences were shown to have a similar SNR arbitrary units (AU) of 6-6.5 in brain white matter, 7-9 in gray matter and 17-18 AU in cerebrospinal fluid. SNR between white and gray matter were significantly different for KB and CN (p = 0.046 and

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdultBrainFemaleHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingMalePhantoms, ImagingReproducibility of ResultsSignal-To-Noise RatioSodium

Substanzen

Sodium

Autor:innen und Institutionen

  • NMR Research Unit, Department of Neuroinflammation, Queen Square MS Centre, UCL Institute of Neurology, Queen Square, London, WC1N 3BG, UK, frank.riemer.10@ucl.ac.uk.

Zitieren

APA

Riemer, F., Solanky, B. S., Stehning, C., Clemence, M., Wheeler-Kingshott, C. A., & Golay, X. (2014). Sodium (23Na) ultra-short echo time imaging in the human brain using a 3D-Cones trajectory. Magnetic Resonance Materials in Physics, Biology and Medicine, 27(1), 35-46. https://doi.org/10.1007/s10334-013-0395-2

Vancouver

Riemer F, Solanky BS, Stehning C, Clemence M, Wheeler-Kingshott CA, Golay X. Sodium (23Na) ultra-short echo time imaging in the human brain using a 3D-Cones trajectory. Magnetic Resonance Materials in Physics, Biology and Medicine. 2014;27(1):35-46. doi:10.1007/s10334-013-0395-2

BibTeX
@article{Riemer2014,
  author = {Riemer, Frank and Solanky, Bhavana S and Stehning, Christian and Clemence, Matthew and Wheeler-Kingshott, Claudia A M and Golay, Xavier},
  title = {Sodium (23Na) ultra-short echo time imaging in the human brain using a 3D-Cones trajectory},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2014},
  volume = {27},
  number = {1},
  pages = {35--46},
  doi = {10.1007/s10334-013-0395-2}
}
Kostenlos starten →