A numerical framework for preprocedural prosthetic valve positioning and hemodynamic evaluation
Biomechanics and Modeling in Mechanobiology · 2026
DOI: 10.1007/s10237-025-02025-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2026. Verfasst von Jonas Lantz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden. Jonas.Lantz@liu.se. Hauptthemen laut MEDLINE: Hemodynamics, Heart Valve Prosthesis, Numerical Analysis, Computer-Assisted, Heart Valve Prosthesis Implantation. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Karolinska Institute, Linköping University.
Abstract (Originalsprache)
Aortic valve replacement is a cornerstone treatment for severe aortic valve diseases, including stenosis and regurgitation. Suboptimal valve seating can elevate the transvalvular pressure gradient, while valve orientation and size may produce flow jets that impinge on the ascending aorta, potentially weakening the vessel wall. Such hemodynamic complications can compromise valve performance and patient outcomes. This study presents a computational fluid dynamics framework, derived from medical CT images, for preprocedural hemodynamic assessment of aortic valve replacement. The framework minimizes user input and delivers rapid results, enabling efficient evaluation of valve types, orientations, and their hemodynamic impact. The results demonstrate that non-optimal implantation angles substantially increase pressure drop across the valve, thereby imposing higher workload on the heart. This automated and efficient simulation framework demonstrates strong potential for clinical application, supporting precise planning and execution of valve implantation procedures to improve patient care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden. Jonas.Lantz@liu.se.
- Center for Image Science and Visualization, Linköping University, Linköping, Sweden. Jonas.Lantz@liu.se.
- Department of Radiology, Mayo Clinic, Rochester, MN, USA. Jonas.Lantz@liu.se.
- Department of Radiology, Mayo Clinic, Rochester, MN, USA.
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
- Center for Image Science and Visualization, Linköping University, Linköping, Sweden.
Förderung
- Karolinska Institute
- Linköping University
Zitieren
APA
Lantz, J., Collins, J. D., Leng, S., McCollough, C. H., Persson, A., & Ebbers, T. (2026). A numerical framework for preprocedural prosthetic valve positioning and hemodynamic evaluation. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-025-02025-7
Vancouver
Lantz J, Collins JD, Leng S, McCollough CH, Persson A, Ebbers T. A numerical framework for preprocedural prosthetic valve positioning and hemodynamic evaluation. Biomechanics and Modeling in Mechanobiology. 2026. doi:10.1007/s10237-025-02025-7
BibTeX
@article{Lantz2026,
author = {Lantz, Jonas and Collins, Jeremy D and Leng, Shuai and McCollough, Cynthia H and Persson, Anders and Ebbers, Tino},
title = {A numerical framework for preprocedural prosthetic valve positioning and hemodynamic evaluation},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2026},
doi = {10.1007/s10237-025-02025-7}
}
EUVIMED