Assessing calcification effects in TEVAR procedures: a computational analysis
Biomechanics and Modeling in Mechanobiology · 2025
DOI: 10.1007/s10237-025-01998-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2025. Verfasst von Giulia De Campo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico Di Milano, Milan, Italy. Hauptthemen laut MEDLINE: Endovascular Aneurysm Repair, Calcinosis, Models, Cardiovascular. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of University and Research.
Abstract (Originalsprache)
Thoracic endovascular aortic repair (TEVAR) procedure is sometimes discouraged from clinical guidelines in the presence of calcifications and thrombus along the sealing zones. This computational study aims to understand which is the effect of calcification on stent graft displacement after TEVAR procedure, simulated in a patient-specific anatomy with a penetrating aortic ulcer (PAU). A patient-specific anatomy without calcification is taken as reference, and four models with idealized calcifications positioned in different regions and with different material properties are analyzed. Opening area, von Mises stresses and contact pressures are evaluated to provide a reliable comparison between the calcified (Ca) and the non-calcified models (noCa), and among the calcified models themselves. Comparing qualitatively the Ca and noCa models, no particular changes in the stent graft apposition are observed. In addition, in the Ca models the opening area results lower with respect to the noCa models, but no significant differences are observed among the Ca models. Regarding the von Mises stresses, it seems that the calcifications act as load-bearing structures, absorbing the stresses and reducing them on the aorta. Decreasing the Young modulus of the calcifications, this effect is reduced. Higher contact pressures are observed when the highest Young’s modulus of calcification is adopted, with all Ca models having greater pressures than the noCa model. From this analysis, the stent graft seems to be positioned correctly inside the aorta, even in the presence of calcifications. In this setting, the calcifications seem to reduce the stresses on the aorta, thus reducing the likelihood of aneurysm rupture.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico Di Milano, Milan, Italy.
- AllStent S.R.L, Milan, Italy.
- Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico Di Milano, Milan, Italy. giulia.luraghi@polimi.it.
- Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy.
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
- Department of Cardiothoracic Surgery, Radboud University Medical Centre, Nijmegen, The Netherlands.
Förderung
- Italian Ministry of University and Research
Zitieren
APA
De Campo, G., Ramella, A., Barati, S., Luraghi, G., Fregona, V., Domanin, M., Heijmen, R., Trimarchi, S., & Migliavacca, F. (2025). Assessing calcification effects in TEVAR procedures: a computational analysis. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-025-01998-9
Vancouver
De Campo G, Ramella A, Barati S, Luraghi G, Fregona V, Domanin M, et al. Assessing calcification effects in TEVAR procedures: a computational analysis. Biomechanics and Modeling in Mechanobiology. 2025. doi:10.1007/s10237-025-01998-9
BibTeX
@article{DeCampo2025,
author = {De Campo, Giulia and Ramella, Anna and Barati, Sara and Luraghi, Giulia and Fregona, Virginia and Domanin, Maurizio and Heijmen, Robin and Trimarchi, Santi and Migliavacca, Francesco},
title = {Assessing calcification effects in TEVAR procedures: a computational analysis},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2025},
doi = {10.1007/s10237-025-01998-9}
}
EUVIMED