EUVIMEDEUVIMED entdecken
Fallbericht

Cannula exchange for refractory cannula infections during Berlin Heart EXCOR support: a case report

Shota Kawai, Takashi Kido, Motoki Komori, Yosuke Kugo, Jun Narita, Hidekazu Ishida, Takayoshi Ueno, Shigeru Miyagawa

Journal of Artificial Organs · 2026-12 · 29 (4)

DOI: 10.1007/s10047-026-01604-4 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Artificial Organs, online erschienen am 10.11.2026. Verfasst von Shota Kawai und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Graduate School of Medicine, The University of Osaka, Osaka, 565-0871, Japan. Hauptthemen laut MEDLINE: Heart Failure, Heart-Assist Devices, Staphylococcal Infections, Cannula. Die Arbeit nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Infection of the cannulae during Berlin Heart EXCOR (BHE) support is a serious complication, with refractory infections often necessitating surgical intervention to prevent their progression to mediastinitis. However, the treatment options for such infections are limited. We report the case of a 4-year-old girl with truncus arteriosus who developed severe heart failure after palliative right ventricular outflow tract reconstruction and aortic valve replacement. The patient successfully underwent a combined surgical procedure consisting of ventricular septal defect and aortic valve closure, redo right ventricular outflow tract reconstruction, and BHE implantation. However, at 10 months after BHE implantation, the outflow cannula exit site was infected by methicillin-resistant Staphylococcus epidermidis. Gallium-67 scintigraphy revealed tracer uptake along the abdominal outflow cannula tract without mediastinal extension. Because the prior aortic valve closure prevented temporary BHE explantation, surgical cannula exchange was performed together with mediastinal irrigation, omental flap transposition, and negative-pressure wound therapy. The infection resolved completely and no recurrent infection was observed during the 1-year follow-up period. In conclusion, cannula exchange combined with omental flap transposition is an effective surgical option for treating refractory cannula infections during BHE support when device explantation is not feasible.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureHeart-Assist DevicesStaphylococcal InfectionsCannulaProsthesis-Related InfectionsHumansFemaleChild, PreschoolStaphylococcus epidermidis

Stichwörter der Autor:innen

Berlin Heart EXCORCannula exchangeCannula infectionDevice-related infectionVentricular assist device

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Graduate School of Medicine, The University of Osaka, Osaka, 565-0871, Japan.
  • Department of Cardiovascular Surgery, Graduate School of Medicine, The University of Osaka, Osaka, 565-0871, Japan. kido.surg1@osaka-u.ac.jp.
  • Department of Pediatrics, Graduate School of Medicine, The University of Osaka, Osaka, 565-0871, Japan.
  • Department of Cardiovascular Surgery, Graduate School of Medicine, The University of Osaka, Osaka, 565-0871, Japan. miyagawa.shigeru.med@osaka-u.ac.jp.

Zitieren

APA

Kawai, S., Kido, T., Komori, M., Kugo, Y., Narita, J., Ishida, H., Ueno, T., & Miyagawa, S. (2026). Cannula exchange for refractory cannula infections during Berlin Heart EXCOR support: a case report. Journal of Artificial Organs, 29(4). https://doi.org/10.1007/s10047-026-01604-4

Vancouver

Kawai S, Kido T, Komori M, Kugo Y, Narita J, Ishida H, et al. Cannula exchange for refractory cannula infections during Berlin Heart EXCOR support: a case report. Journal of Artificial Organs. 2026;29(4). doi:10.1007/s10047-026-01604-4

BibTeX
@article{Kawai2026,