EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Computational analysis of thrombosis risk with variations in left ventricular assist device inflow cannula design in a multi-patient model

Mehrdad Khamooshi, Marjan Azimi, Shaun D Gregory

Computer Methods and Programs in Biomedicine · 2023

DOI: 10.1016/j.cmpb.2023.107730 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2023. Verfasst von Mehrdad Khamooshi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cardio-Respiratory Engineering and Technology Laboratory (CREATElab), Department of Mechanical and Aerospace Engineering, Monash University, Melbourn…. Hauptthemen laut MEDLINE: Heart-Assist Devices, Thrombosis, Heart Failure. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Heart Foundation of Australia, National Health and Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: Left ventricular assist devices (LVADs) are mechanical pumps used to support patients with end-stage heart failure. The inflow cannula is a critical component of the LVAD as it connects the pump to the left ventricle, allowing blood to be drawn from the heart. However, the design of the cannula can significantly impact LV hemodynamics and cause complications, including thrombosis. Therefore, this study aimed to analyze the numerical effects of left ventricle (LV) size on cannula design in order to enhance hemodynamic performance using post-operative left ventricular assist device (LVAD) models. METHODS: A parametric design evaluation of two different inflow cannulas were carried out on left ventricles (LV) of varying sizes (ranging from 154 to 430 ml) constructed from computerized tomography (CT) data from VAD patients using computational fluid dynamics (CFD) simulations. The study analyzed three key factors contributing to thrombosis formation: blood residence time, blood stagnation ratio, and wall shear stress. RESULTS: Results showed higher blood residence time and stagnation ratio for larger left ventricular sizes. In addition, increasing the insertion length of the cannula reduced the average wall shear stress. CONCLUSION: Overall, the study's findings suggest that the optimal cannula shape for LVADs varies with left ventricular size.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesThrombosisHeart FailureHumansCannulaHeart VentriclesTomography, X-Ray ComputedHemodynamics

Stichwörter der Autor:innen

CFDLVADResidenceThrombosisWashout

Autor:innen und Institutionen

  • Cardio-Respiratory Engineering and Technology Laboratory (CREATElab), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia. Electronic address: mehrdad.khamooshi@monash.edu.
  • Cardio-Respiratory Engineering and Technology Laboratory (CREATElab), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia.

Förderung

  • National Heart Foundation of Australia
  • National Health and Medical Research Council

Zitieren

APA

Khamooshi, M., Azimi, M., & Gregory, S. D. (2023). Computational analysis of thrombosis risk with variations in left ventricular assist device inflow cannula design in a multi-patient model. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2023.107730

Vancouver

Khamooshi M, Azimi M, Gregory SD. Computational analysis of thrombosis risk with variations in left ventricular assist device inflow cannula design in a multi-patient model. Computer Methods and Programs in Biomedicine. 2023. doi:10.1016/j.cmpb.2023.107730

BibTeX
@article{Khamooshi2023,
  author = {Khamooshi, Mehrdad and Azimi, Marjan and Gregory, Shaun D},
  title = {Computational analysis of thrombosis risk with variations in left ventricular assist device inflow cannula design in a multi-patient model},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2023},
  doi = {10.1016/j.cmpb.2023.107730}
}
Kostenlos starten →