EUVIMEDEUVIMED entdecken
Crossref

Investigating optimal drainage cannula for venovenous extracorporeal membrane oxygenation: impact of side holes on blood oxygenation – an in vitro study

Konomi Togo

Journal of Artificial Organs · 2025

DOI: 10.1007/s10047-025-01525-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Artificial Organs, 2025. Verfasst von Konomi Togo. Beteiligte Einrichtung: Department of Medical Course, Faculty of Health and Medical Science, Teikyo Heisei University, 2-51-4 Higashiikebukuro, Toshima-ku, Tokyo, 170-8445, …. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Cannula, Drainage, Oxygen. Die Arbeit nennt 9 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Venovenous extracorporeal membrane oxygenation (VV ECMO) relies on effective blood drainage, and cannula design plays a crucial role in optimizing blood oxygenation. Recirculation, where oxygenated blood returns to the drainage cannula without systemic circulation, can negatively impact ECMO efficacy. It was hypothesized that drainage cannulae with a longer side hole portion would reduce recirculation and improve blood oxygenation. This in vitro study investigated the impact of the length of the side hole portion and the intervals of the side holes on blood oxygenation in a simulated VV ECMO circuit. Five cannulae were prepared with the following side holes: (a) 1-cm intervals from the tip to 5 cm; (b) 1-cm intervals from the tip to 10 cm; (c) 1-cm intervals from the tip to 15 cm; (d) 3-cm intervals from the tip to 15 cm; and e) 5-cm intervals from the tip to 15 cm. With blood drained from the right atrium and returned to the superior vena cava, recirculation rates and PaO2 at 150 s after ECMO initiation (descending PaO2 order) were: (c) 32 ± 1% and 160 ± 4 mmHg; (d) 35 ± 1% and 149 ± 5 mmHg; (b) 38 ± 1% and 139 ± 5 mmHg; (e) 39 ± 1% and 133 ± 4 mmHg; and (a) 57 ± 3% and 94 ± 7 mmHg. These findings suggest that cannulae with a longer side hole portion may optimize blood oxygenation by reducing recirculation. Furthermore, shorter side hole portions on drainage cannulae are not recommended for VV ECMO.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracorporeal Membrane OxygenationCannulaDrainageOxygenHumansEquipment DesignIn Vitro Techniques

Stichwörter der Autor:innen

Blood oxygenationDrainage cannulaRecirculationSide holeVenovenous extracorporeal membrane oxygenation

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Medical Course, Faculty of Health and Medical Science, Teikyo Heisei University, 2-51-4 Higashiikebukuro, Toshima-ku, Tokyo, 170-8445, Japan. k.togo@thu.ac.jp.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Togo, K. (2025). Investigating optimal drainage cannula for venovenous extracorporeal membrane oxygenation: impact of side holes on blood oxygenation – an in vitro study. Journal of Artificial Organs. https://doi.org/10.1007/s10047-025-01525-8

Vancouver

Togo K. Investigating optimal drainage cannula for venovenous extracorporeal membrane oxygenation: impact of side holes on blood oxygenation – an in vitro study. Journal of Artificial Organs. 2025. doi:10.1007/s10047-025-01525-8

BibTeX
@article{Togo2025,
  author = {Togo, Konomi},
  title = {Investigating optimal drainage cannula for venovenous extracorporeal membrane oxygenation: impact of side holes on blood oxygenation – an in vitro study},
  journal = {Journal of Artificial Organs},
  year = {2025},
  doi = {10.1007/s10047-025-01525-8}
}
Kostenlos starten →