EUVIMEDEUVIMED entdecken
Crossref

Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law hemolysis model

Ahmet Onder, Omer Incebay, Rafet Yapici

Journal of Artificial Organs · 2025-06 · 28 (2) · 184-191

DOI: 10.1007/s10047-024-01468-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Artificial Organs, online erschienen am 23.08.2024. Verfasst von Ahmet Onder und 2 weiteren Autor:innen. Beteiligte Einrichtung: Technical Sciences Vocational School, Mechanical and Metal Technologies Department, Konya Technical University, Konya, Turkey. aonder@ktun.edu.tr. Hauptthemen laut MEDLINE: Hemolysis, Hydrodynamics, Heart-Assist Devices, Computer Simulation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hemolysis is the most important issue to consider in the design and optimization of blood-contacting devices. Although the use of Computational Fluid Dynamics (CFD) in hemolysis prediction studies provides convenience and has promising potential, it is an extremely challenging process. Hemolysis predictions with CFD depend on the mesh, implementation method, coefficient set, and scalar-shear-stress model. To this end, an attempt was made to find the combination that would provide the most accurate result in hemolysis prediction with the commonly cited power-law based hemolysis model. In the hemolysis predictions conducted using CFD on the Food and Drug Administration (FDA) benchmark blood pump, 3 different scalar-shear-stress models, and 5 different coefficient sets with the power-law based hemolysis model were used. Also, a mesh independence test based on hemolysis and pressure head was performed. The pressure head results of CFD simulations were compared with published pressure head of the FDA benchmark blood pump and a good agreement was observed. In addition, results of CFD-hemolysis predictions which are conducted with scalar-shear-stress model and coefficient set combinations were compared with experimental hemolysis data at three operating conditions such as 6-7 L/min flow rates at 3500 rpm rotational speeds and 6 L/min at 2500 rpm. One of the combinations of the scalar-shear-stress model and the coefficient set was found to be within the error limits of the experimental measurements, while all other combinations overestimated hemolysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemolysisHydrodynamicsHeart-Assist DevicesComputer SimulationStress, MechanicalUnited States Food and Drug AdministrationUnited StatesHumansEquipment DesignModels, Cardiovascular

Stichwörter der Autor:innen

CFDCentrifugal blood pumpHemolysisScalar shear stress

Autor:innen und Institutionen

  • Technical Sciences Vocational School, Mechanical and Metal Technologies Department, Konya Technical University, Konya, Turkey. aonder@ktun.edu.tr.
  • Faculty of Engineering and Natural Science, Mechanical Engineering Department, Konya Technical University, Konya, Turkey.

Zitieren

APA

Onder, A., Incebay, O., & Yapici, R. (2025). Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law hemolysis model. Journal of Artificial Organs, 28(2), 184-191. https://doi.org/10.1007/s10047-024-01468-6

Vancouver

Onder A, Incebay O, Yapici R. Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law hemolysis model. Journal of Artificial Organs. 2025;28(2):184-191. doi:10.1007/s10047-024-01468-6

BibTeX
@article{Onder2025,
  author = {Onder, Ahmet and Incebay, Omer and Yapici, Rafet},
  title = {Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law hemolysis model},
  journal = {Journal of Artificial Organs},
  year = {2025},
  volume = {28},
  number = {2},
  pages = {184--191},
  doi = {10.1007/s10047-024-01468-6}
}
Kostenlos starten →