Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 28.10.2026. Verfasst von Shuaizhi Zhou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Central Hospital of Dalian University of Technology, No.826 Southwest Road, Shahekou District, Dalian, 116021, Liaoning, China. Hauptthemen laut MEDLINE: Hemodynamics, Computer Simulation, Aorta, Heart-Assist Devices. Die Arbeit nennt 70 Literaturangaben. Gefördert von: National Heart Foundation of Australia, National Health and Medical Research Council of Australia, Liaoning Province Science and Technology Plan Joint Plan Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intra-aortic rotary blood pump (IARBP) can improve cardiac and renal function for cardiorenal syndrome (CRS) patients. However, the mechanism of hemodynamic changes in the aorta caused by IARBP is not fully understood. Therefore, this study quantitatively analyzed the aortic hemodynamic effects with IARBP support to evaluate its potential clinical benefits and risks. A three-dimensional aortic model was established from patient-specific image data and coupled with an IARBP. Hemodynamic characteristics and potential blood damage in the aorta under different IARBP speed modes, including flow field, blood flow velocity, pressure, wall shear stress-related indices, scalar shear stress (SSS), and hemolysis index (HI), were systematically evaluated using computational fluid dynamics (CFD). Results showed that constant-speed IARBP support increased downstream aortic flow velocity and pressure by 30.79% and 5.28%, respectively. The pump-outlet jet impinged on the aortic wall, creating localized regions with wall shear stress (WSS) exceeding 40 Pa and potentially increasing the risk of vascular endothelial injury. Compared with the constant speed mode, pulsatile speed modes further reduced low WSS areas to lower atherosclerosis risk, especially that counterpulsation mode increased renal blood flow by 19.33% and reduced HI by 14.4%, but was less favorable for cerebral and upper-limb perfusion. Copulsation mode performed better in this regard. Overall, this study verified the potential clinical benefits and risks of IARBP especially at pulsatile speeds in optimizing downstream and upstream perfusion and reducing vascular adverse events, which could provide support and guidance for optimizing IARBP speed and its clinical treatment strategy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemodynamicsComputer SimulationAortaHeart-Assist DevicesNumerical Analysis, Computer-AssistedHumansStress, MechanicalModels, CardiovascularBlood Flow VelocityShear StrengthHydrodynamicsPulsatile FlowHemolysis

Stichwörter der Autor:innen

Cardiorenal syndromeComputational fluid dynamicsHemodynamic effectsIntra-aortic rotary blood pumpPulsatile pump speed

Autor:innen und Institutionen

  • Central Hospital of Dalian University of Technology, No.826 Southwest Road, Shahekou District, Dalian, 116021, Liaoning, China.
  • School of Mechanical Engineering, Dalian University of Technology, Dalian, Liaoning, China.
  • Department of Bioengineering, University of Louisville, Louisville, KY, 40292, USA.
  • School of Biomedical Engineering, Faculty of Medicine, Ganjingzi District, Dalian University of Technology, No.2 Linggong Road, Dalian, 116024, Liaoning, China.
  • Jefferson County Public Schools, Louisville, KY, 40218, USA.
  • School of Mechanical, Medical, and Process Engineering and the Centre for Biomedical Technologies, Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, 4000, Australia.

Förderung

  • National Heart Foundation of Australia
  • National Health and Medical Research Council of Australia
  • Liaoning Province Science and Technology Plan Joint Plan Project
  • Fundamental Research Funds for the Central Universities of China

Zitieren

APA

Zhou, S., Giridharan, G. A., Chen, R., El-Baz, A., Gregory, S. D., Qu, P., Song, Y., Mu, X., & Wang, Y. (2026). Numerical simulation of aortic hemodynamic effects modulated by the intra-aortic rotary blood pump with different speed modes. Biomechanics and Modeling in Mechanobiology, 25(6). https://doi.org/10.1007/s10237-026-02143-w

Vancouver

Zhou S, Giridharan GA, Chen R, El-Baz A, Gregory SD, Qu P, et al. Numerical simulation of aortic hemodynamic effects modulated by the intra-aortic rotary blood pump with different speed modes. Biomechanics and Modeling in Mechanobiology. 2026;25(6). doi:10.1007/s10237-026-02143-w

BibTeX
@article{Zhou2026,
  author = {Zhou, Shuaizhi and Giridharan, Guruprasad A and Chen, Rui and El-Baz, Ahmed and Gregory, Shaun D and Qu, Peng and Song, Yang and Mu, Xiaolin and Wang, Yu},
  title = {Numerical simulation of aortic hemodynamic effects modulated by the intra-aortic rotary blood pump with different speed modes},
  journal = {Biomechanics and Modeling in Mechanobiology},
  year = {2026},
  volume = {25},
  number = {6},
  doi = {10.1007/s10237-026-02143-w}
}
Kostenlos starten →