EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AI–driven reconstruction of maxillary complete denture bases: a clinical feasibility study

Omnia Saleh, Benedikt C. Spies, Marc C. Metzger, Brian Goodacre, Aiste Kernen-Gintaute, Felix Burkhardt

Clinical Oral Investigations · 20.11.2026 · 30 (12)

DOI: 10.1007/s00784-026-07279-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 20.11.2026. Verfasst von Omnia Saleh und 5 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Freiburg.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Digital denture workflows remain limited by the inability of intraoral scanners (IOS) to capture functional soft-tissue dynamics and peripheral border molding. This clinical feasibility study evaluated whole-surface geometric reconstruction of maxillary complete denture bases from IOS data using a novel artificial intelligence (AI) model in which peripheral border features were emphasized during training. Materials and methods IOS datasets of the edentulous maxilla and corresponding clinically acceptable dentures from 79 patients were used to train an enhanced PointNet + + model incorporating a border-attention mechanism. The dataset was divided into 57 training, 7 validation, and 15 test cases. Whole-surface point-cloud performance was evaluated in the held-out test set using Density-Aware Chamfer Distance, maximum Hausdorff distance, and multi-threshold precision, recall, and F-scores. Whole-surface registration RMSE was additionally calculated for three randomly selected test-set cases that underwent additive manufacturing and an exploratory clinical try-in.

Results

On an independent test set, the mean Chamfer Distance was 2.6 ± 0.1 mm and the maximum Hausdorff distance was 2.4 mm. F-scores increased from 0.8 at a 0.5-mm tolerance to 1.0 at a 2.0-mm tolerance. Whole-surface RMSE values for the three pilot cases ranged from 0.4 to 0.6 mm. The additively manufactured AI denture bases showed promising adaptation and positional stability in this pilot evaluation; however, conventionally fabricated dentures provided superior retention.

Conclusions

Within the study’s limitations, the AI model showed potential for whole-surface reconstruction of maxillary denture bases from IOS data. However, in the descriptive try-in of three cases, the patients’ existing conventional dentures were subjectively more retentive than the additively manufactured AI-generated bases. Clinical relevance AI-based denture-base reconstruction from IOS data may contribute to future fully digital workflows. Before clinical implementation, border-specific geometric validation, larger external datasets, and objective measurements of retention, adaptation, and positional stability are required.

Förderung

  • Universitätsklinikum Freiburg

Zitieren

APA

Saleh, O., Spies, B. C., Metzger, M. C., Goodacre, B., Kernen-Gintaute, A., & Burkhardt, F. (2026). AI–driven reconstruction of maxillary complete denture bases: a clinical feasibility study. Clinical Oral Investigations, 30(12). https://doi.org/10.1007/s00784-026-07279-8

Vancouver

Saleh O, Spies BC, Metzger MC, Goodacre B, Kernen-Gintaute A, Burkhardt F. AI–driven reconstruction of maxillary complete denture bases: a clinical feasibility study. Clinical Oral Investigations. 2026;30(12). doi:10.1007/s00784-026-07279-8

BibTeX
@article{Saleh2026,
  author = {Saleh, Omnia and Spies, Benedikt C. and Metzger, Marc C. and Goodacre, Brian and Kernen-Gintaute, Aiste and Burkhardt, Felix},
  title = {AI–driven reconstruction of maxillary complete denture bases: a clinical feasibility study},
  journal = {Clinical Oral Investigations},
  year = {2026},
  volume = {30},
  number = {12},
  doi = {10.1007/s00784-026-07279-8}
}
Kostenlos starten →