Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 22.12.2025. Verfasst von Bahaaeldeen M Elgarba und 5 weiteren Autor:innen. Beteiligte Einrichtung: OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Artificial Intelligence, Dental Implants, Dental Implantation, Endosseous, Surgery, Computer-Assisted. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The researcher (Bahaaeldeen M. Elgarba) is funded by a full scholarship (GM01-2020) from the Ministry of Higher Education of the Arab Republic of Egypt..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the clinical validity of artificial intelligence (AI)‐driven virtual implant placement compared to human intelligence (HI)‐based virtual and actual single implant placement in the posterior mandible. Material and Methods Thirty‐two patients for whom experts performed single implant placement in the posterior mandible were included, each with preoperative and postoperative cone‐beam computed tomography (CBCT) scans. The preoperative scans were registered to the corresponding postoperative scans and used for both AI‐ and HI‐driven virtual implant planning at the implant site. From each case, three implants' scenarios (i.e., HI‐placed, AI‐planned, and HI‐planned) were exported and compared. The analysis focused on angular deviation and the spatial relationship of each implant to adjacent anatomical structures and the expert‐designed prosthetic wax‐up. In addition, pairwise comparisons were performed to quantify angular and linear deviations at both the coronal and apical levels. Implant length and diameter from planned versus placed implants were evaluated, and planning time and consistency were compared between AI‐ and HI‐based approaches.

Results

AI‐based planning showed no statistically significant differences compared to HI‐based methods observed in angular deviation relative to adjacent tooth (HI‐placed: 7.7° ± 5.6°, AI: 6° ± 4.7°, HI‐planned: 5.2° ± 5.7°) and coronal deviation (AI vs. HI‐placed: 0.9 ± 0.8 mm, AI vs. HI‐planned: 0.8 ± 0.4 mm, HI‐planned vs. HI‐placed: 1.0 ± 1.1 mm), all with p > 0.05. Implant diameter and length were also consistent across the different approaches, with HI‐placed (4.3 ± 0.3 mm; 9.7 ± 1.3 mm), AI (4.3 ± 0.4 mm; 9.9 ± 1.2 mm), and HI‐planned (4.3 ± 0.4 mm; 9.8 ± 1.3 mm) showing no significant differences ( p > 0.05). However, AI planning was significantly faster (36.3 ± 7.3 s vs. 373 ± 113 s) and more consistent, with a median surface deviation of 0 mm compared to 0.39 mm for HI ( p < 0.05).

Conclusion

The AI tool showed clinically valid implant selection, matched expert placement and planning in virtual implant positioning for missing mandibular premolars and molars while being highly consistent and 10 times faster compared to human expert planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceDental ImplantsDental Implantation, EndosseousSurgery, Computer-AssistedFeasibility StudiesMandibleHumansCone-Beam Computed TomographyWorkflowRetrospective StudiesMaleFemaleAdultMiddle AgedAgedCross-Sectional Studies

Stichwörter der Autor:innen

3D imagingartificial intelligencecone‐beam computed tomographydental implantimplant dentistry

Substanzen

Dental Implants

Autor:innen und Institutionen

  • OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium.
  • Department of Prosthodontics, Faculty of Dentistry, Tanta University, Tanta, Egypt.
  • Department of Oral and Maxillofacial Surgery, University Hospitals, Leuven, Belgium.
  • Department of Stomatology, Public Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, Brazil.
  • Division of Periodontology and Oral Microbiology, Department of Oral Health Sciences, KU Leuven, Leuven, Belgium.
  • Department of Conservative Dentistry, Periodontology and Digital Dentistry, LMU University Hospital, LMU Munich, Munich, Germany.

ORCID-Profile: Bahaaeldeen M Elgarba, Rocharles Cavalcante Fontenele, Eslam Abdelwahab Dawood, Pierre Lahoud, Jan Meeus, Reinhilde Jacobs

Förderung

  • The researcher (Bahaaeldeen M. Elgarba) is funded by a full scholarship (GM01-2020) from the Ministry of Higher Education of the Arab Republic of Egypt.

Zitieren

APA

Elgarba, B. M., Fontenele, R. C., Dawood, E. A., Lahoud, P., Meeus, J., & Jacobs, R. (2025). Clinical Feasibility of AI ‐Driven Automated Virtual Dental Implant Placement: A Cross‐Sectional Comparative Study. Clinical Implant Dentistry and Related Research, 27(6). https://doi.org/10.1111/cid.70111

Vancouver

Elgarba BM, Fontenele RC, Dawood EA, Lahoud P, Meeus J, Jacobs R. Clinical Feasibility of AI ‐Driven Automated Virtual Dental Implant Placement: A Cross‐Sectional Comparative Study. Clinical Implant Dentistry and Related Research. 2025;27(6). doi:10.1111/cid.70111

BibTeX
@article{Elgarba2025,
  author = {Elgarba, Bahaaeldeen M and Fontenele, Rocharles Cavalcante and Dawood, Eslam Abdelwahab and Lahoud, Pierre and Meeus, Jan and Jacobs, Reinhilde},
  title = {Clinical Feasibility of AI ‐Driven Automated Virtual Dental Implant Placement: A Cross‐Sectional Comparative Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  volume = {27},
  number = {6},
  doi = {10.1111/cid.70111}
}
Kostenlos starten →